Literature DB >> 9127076

Failure strength of a new meniscus arrow repair technique: biomechanical comparison with horizontal suture.

P Albrecht-Olsen1, T Lind, G Kristensen, B Falkenberg.   

Abstract

A new method for arthroscopic all-inside repair of vertical meniscus lesions by use of a biodegradable fixation device ("meniscus arrow") has been developed, including a set of cannulas for easy insertion via standard arthroscopic portals. The technique is described. A study to test the fixation properties was performed in the laboratory. Twenty-four fresh frozen bovine medial menisci were defreezed and divided into three groups. In all menisci an artificial vertical lesion was created with a scalpel 3mm from the peripheral rim. Repair in group I was done with a single horizontal Maxon-O suture using an Acufex double-barrel cannula (Acufex Meniscal Stitcher; Acufex Microsurgical, Norwood, MA). A knot was tied on the capsular side. Repair in group II was made with one 13 mm Biofix Meniscus arrow (Bioscience Ltd, Tampere, Finland). In group III repair was performed like in group II but the menisci were incubated in isotonic saline at 21 degrees C for 24 hours before testing. Menisci in group I and II were tested within 3 hours after defreezing. Prior to testing total separation of central and peripheral part of meniscus was performed. Thus only the repair site was tested. Pull-out tests to failure were made in a computer-based Nene M5 testing machine with a cross-head speed of 5 mm/min. Median failure load in group I: 49 N (range 43 to 77 N), in group II: 53 N (range 42 to 65 N) and in group III: 54 N (range 35 to 74 N). No statistically significant differences in failure load was found between the groups. Thus initial failure strength for arrow-repaired bovine menisci is comparable to that of a horizontal suture.

Entities:  

Mesh:

Year:  1997        PMID: 9127076     DOI: 10.1016/s0749-8063(97)90153-5

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  11 in total

1.  Arthroscopic meniscus repair: inside-out technique vs. Biofix meniscus arrow.

Authors:  Franky Steenbrugge; René Verdonk; Chan Hürel; Koen Verstraete
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-09-26       Impact factor: 4.342

2.  A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.

Authors:  Thore Zantop; Anne Kathleen Eggers; Volker Musahl; Andre Weimann; Joachim Hassenpflug; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-12-19       Impact factor: 4.342

Review 3.  All-inside meniscal repair using the FasT-Fix meniscal repair system: is still needed to avoid weight bearing? A systematic review.

Authors:  Alberto Vascellari; Enrico Rebuzzi; Stefano Schiavetti; Nicolò Coletti
Journal:  Musculoskelet Surg       Date:  2012-07-07

4.  Mechanical comparison of meniscal repair devices with mattress suture devices in vitro.

Authors:  Brian C Aros; Angela Pedroza; William K Vasileff; Alan S Litsky; David C Flanigan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-09       Impact factor: 4.342

5.  Evaluation of the second-generation meniscus arrow in the fixation of bucket-handle tears in the vascular area of the meniscus. A prospective study of 20 patients with a mean follow-up of 26 months.

Authors:  Janne Sarimo; Jussi Rantanen; Tapio Tarvainen; Markku Härkönen; Sakari Orava
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-05-05       Impact factor: 4.342

6.  What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes.

Authors:  Francois Hardeman; Kristoff Corten; Michiel Mylle; Bert Van Herck; René Verdonk; Peter Verdonk; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-12       Impact factor: 4.342

Review 7.  Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures?

Authors:  Daniel M Buckland; Patrick Sadoghi; Matthias D Wimmer; Patrick Vavken; Geert I Pagenstert; Victor Valderrabano; Claudio Rosso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-20       Impact factor: 4.342

Review 8.  [Complications with all-inside devices used in reconstructive meniscal surgery].

Authors:  P Wilmes; O Lorbach; P Brogard; R Seil
Journal:  Orthopade       Date:  2008-11       Impact factor: 1.087

9.  MRI of menisci repaired with bioabsorbable arrows.

Authors:  Antti O T Mustonen; Laura Tielinen; Jan Lindahl; Eero Hirvensalo; Martti Kiuru; Seppo K Koskinen
Journal:  Skeletal Radiol       Date:  2006-03-18       Impact factor: 2.199

10.  MRI signal changes in completely healed meniscus confirmed by second-look arthroscopy after meniscal repair with bioabsorbable arrows.

Authors:  Yu Miao; Jia-kuo Yu; Zhuo-zhao Zheng; Chang-long Yu; Ying-fang Ao; Xi Gong; Yong-jian Wang; Dong Jiang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-02-17       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.