W Brodner1, P Bitzan, V Meisinger, A Kaider, F Gottsauner-Wolf, R Kotz.
Abstract
We determined serum cobalt levels in 55 patients by atomic absorption spectrophotometry before and after implantation of uncemented total hip arthroplasties. In a randomised, prospective trial 27 wrought Co-28Cr-6Mo-0.2C metal-on-metal articulations were compared with 28 ceramic-on-polyethylene hips which did not contain cobalt. Other sources of iatrogenic cobalt loading were excluded. The metal-on-metal group produced detectable serum cobalt levels (median 1.1 microg/l after one year) which were significantly different (p < 0.0001) from those of the ceramic-on-polyethylene control group (median below detection limit of 0.3 microg/l after one year). Our findings indicate that metal-on-metal bearings generate some systemic release of cobalt.Entities:
Mesh:
Substances:
Year: 1997 PMID: 9119865 DOI: 10.1302/0301-620x.79b2.7326
Source DB: PubMed Journal: J Bone Joint Surg Br ISSN: 0301-620X