Literature DB >> 9110190

How does computer-assisted digital wall motion analysis influence observer agreement and diagnostic accuracy during stress echocardiography?

K Bjørnstad1, S Aakhus, H G Torp.   

Abstract

This study assessed interobserver and intraobserver variation and diagnostic accuracy during 25 dipyridamole stress echocardiography tests interpreted with different analysis systems: a) computer display of high frame rate digital cineloops (47 frames/s); b) computer display of lower frame rate digital cineloops (24 frames/s); and c) videotape recordings. The majority of the patients (84%) had documented coronary artery disease with baseline wall motion abnormalities due to previous myocardial infarctions and/or coronary bypass surgery, thus comprising a population with difficult interpretation of stress echocardiography. Diagnostic accuracy was assessed using coronary angiography as reference method. Interobserver and intraobserver agreement was highest when analysis was performed from computer-displayed cineloops, 96 and 92%, respectively, compared to 84 and 80% respectively, using videotape recordings. Sensitivity for identification of coronary artery stenosis was similar using digital cineloops with high frame rate or videotape recordings (67% to 80% for both systems), and tended to be lower using cineloops with lower frame rate for analysis (53%). Inter- and intraobserver differences for wall motion score index were not significantly influenced by the analysis system. We conclude that computer assisted analysis with high frame rate of the displayed cineloops provides optimal observer agreement and diagnostic accuracy in the same range as videotape analysis in patients undergoing stress echocardiography.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9110190     DOI: 10.1023/a:1005752331136

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  25 in total

Review 1.  Stress echocardiography versus radionuclide stress techniques.

Authors:  C A Roldan; M H Crawford
Journal:  Echocardiography       Date:  1992-03       Impact factor: 1.724

Review 2.  Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms.

Authors:  N B Schiller; P M Shah; M Crawford; A DeMaria; R Devereux; H Feigenbaum; H Gutgesell; N Reichek; D Sahn; I Schnittger
Journal:  J Am Soc Echocardiogr       Date:  1989 Sep-Oct       Impact factor: 5.251

3.  High dose dipyridamole echocardiography test in effort angina pectoris.

Authors:  E Picano; F Lattanzi; M Masini; A Distante; A L'Abbate
Journal:  J Am Coll Cardiol       Date:  1986-10       Impact factor: 24.094

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Digital subtraction high-frame-rate echocardiography in detecting delayed onset of regional left ventricular relaxation in ischemic heart disease.

Authors:  H Kondo; T Masuyama; K Ishihara; T Mano; K Yamamoto; J Naito; R Nagano; S Kishimoto; J Tanouchi; M Hori
Journal:  Circulation       Date:  1995-01-15       Impact factor: 29.690

6.  Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilatation. I. Physiologic basis and experimental validation.

Authors:  K L Gould
Journal:  Am J Cardiol       Date:  1978-02       Impact factor: 2.778

7.  Hierarchy of levels of ischemia-induced impairment in regional left ventricular systolic function in man.

Authors:  A M Zeiher; H Wollschlaeger; T Bonzel; W Kasper; H Just
Journal:  Circulation       Date:  1987-10       Impact factor: 29.690

8.  Prognostic value of predischarge 2-dimensional echocardiogram after acute myocardial infarction.

Authors:  R A Nishimura; G S Reeder; F A Miller; D M Ilstrup; C Shub; J B Seward; A J Tajik
Journal:  Am J Cardiol       Date:  1984-02-01       Impact factor: 2.778

9.  Prognostic usefulness of positive or negative exercise stress echocardiography for predicting coronary events in ensuing twelve months.

Authors:  J Krivokapich; J S Child; R S Gerber; V Lem; D Moser
Journal:  Am J Cardiol       Date:  1993-03-15       Impact factor: 2.778

10.  Digital dipyridamole stress echocardiography in silent ischemia after coronary artery bypass grafting and/or after healing of acute myocardial infarction.

Authors:  K Bjoernstad; S Aakhus; J Lundbom; K D Bolz; R Rokseth; T Skjaerpe; L Hatle
Journal:  Am J Cardiol       Date:  1993-09-15       Impact factor: 2.778

View more
  3 in total

1.  A meta-analytic comparison of echocardiographic stressors.

Authors:  Yoshinori Noguchi; Shizuko Nagata-Kobayashi; James E Stahl; John B Wong
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

2.  Local cardiac wall stabilization influences the reproducibility of regional wall motion during off-pump coronary artery pass surgery.

Authors:  T Shiga; K Terajima; J Matsumura; A Sakamoto; R Ogawa
Journal:  J Clin Monit Comput       Date:  2000-01       Impact factor: 2.502

3.  Stress echocardiography for the diagnosis of coronary artery disease: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-06-01
  3 in total