Measurements of ultrasonic pulse distortion produced by human chest wall.

L M Hinkelman1, T L Szabo, R C Waag.   

Abstract

Ultrasonic wavefront distortion produced by transmission through human chest wall specimens was measured over a two-dimensional aperture. Measured pulse wavefronts were sometimes disrupted by secondary wavefronts produced by interaction between the transmitted pulses and the bone and cartilage structures of the rib cage. The secondary wavefronts produced large distortions in the received waveforms and interfered with the determination of the wavefront distortion caused by soft-tissue inhomogeneities. The effects of secondary wavefronts were minimized by reducing the region of analysis. Differences in arrival time and energy level between these restricted regions and references that account for geometric delay and spreading were computed. Spectral changes were assessed by calculating a waveform similarity factor that is decreased from 1.0 by changes in waveform shape. For 16 different intercostal spaces, the arrival time fluctuations of the measured waveforms had an average (+/-s.d.) rms value of 21.3 (+/-8.4) ns and an average correlation length of 2.50 (+/-0.62) mm. The energy level fluctuations had an average rms value of 1.57 (+/-0.45) dB and an average correlation length of 1.98 (+/-0.33) mm, and the average waveform similarity factor was 0.964 (+/-0.012). For soft-tissue inhomogeneities in chest wall specimens, the average rms arrival time and energy level fluctuations were less than half those measured for the abdominal wall. However, although the average correlation length of the arrival time fluctuations was less than half that found for the abdominal wall, the average correlation length of the energy level fluctuations was similar to that of the abdominal wall.

Entities:  

Mesh:

Year:  1997        PMID: 9104034     DOI: 10.1121/1.418248

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  8 in total

1.  Unsupervised clustering method to convert high-resolution magnetic resonance volumes to three-dimensional acoustic models for full-wave ultrasound simulations.

Authors:  Kevin Looby; Carl D Herickhoff; Christopher Sandino; Tao Zhang; Shreyas Vasanawala; Jeremy J Dahl
Journal:  J Med Imaging (Bellingham)       Date:  2019-07-22

2.  Blocked Elements in 1-D and 2-D Arrays-Part I: Detection and Basic Compensation on Simulated and In Vivo Targets.

Authors:  Marko Jakovljevic; Gianmarco F Pinton; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-03-16       Impact factor: 2.725

3.  Blocked Elements in 1-D and 2-D Arrays-Part II: Compensation Methods as Applied to Large Coherent Apertures.

Authors:  Marko Jakovljevic; Nick Bottenus; Lily Kuo; Shalki Kumar; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-03-16       Impact factor: 2.725

4.  Sources of image degradation in fundamental and harmonic ultrasound imaging: a nonlinear, full-wave, simulation study.

Authors:  Gianmarco F Pinton; Gregg E Trahey; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

5.  Sources of image degradation in fundamental and harmonic ultrasound imaging using nonlinear, full-wave simulations.

Authors:  Gianmarco F Pinton; Gregg E Trahey; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-04       Impact factor: 2.725

6.  Short-lag spatial coherence imaging of cardiac ultrasound data: initial clinical results.

Authors:  Muyinatu A Lediju Bell; Robi Goswami; Joseph A Kisslo; Jeremy J Dahl; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2013-08-09       Impact factor: 2.998

7.  Experimental Measurements of Ultrasound Attenuation in Human Chest Wall and Assessment of the Mechanical Index for Lung Ultrasound.

Authors:  Brandon Patterson; Douglas L Miller
Journal:  Ultrasound Med Biol       Date:  2020-03-24       Impact factor: 2.998

8.  Assessing the Robustness of Frequency-Domain Ultrasound Beamforming Using Deep Neural Networks.

Authors:  Adam C Luchies; Brett C Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-15       Impact factor: 3.267

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.