Frequency-selective fat suppression MR imaging. Localized asymmetric failure of fat suppression mimicking orbital disease.

A R Borges1, R B Lufkin, A Y Huang, K Farahani, A C Arnold.   

Abstract

Our objectives were to further characterize an artifact related to the localized failure of the frequency-selective (FATSAT) fat suppression magnetic resonance (MR) imaging technique. We constructed two phantoms simulating human orbital anatomy and imaged them on a 1.5-T MR scanner using (FATSAT) and short T1 inversion recovery (STIR) techniques of fat suppression. The first phantom resembled orbit structural configurations; it was imaged in coronal and axial planes and in varying orientations with respect to the main magnetic field (Z axis) to study the features of the artifact and to reproduce the asymmetry seen in clinical cases. We designed the second phantom to enable quantification of the change in artifact size with change in orientation. We imaged the orbits of a normal human volunteer in similar planes and orientations, and compared the results to clinical cases demonstrating the artifact and true orbital disease. The artifact identified with localized failure of FATSAT fat suppression manifested as regions of hyperintensity maximal at fat-air interfaces, with gradual fading of the increased signal with distance from the interfaces. The artifact was most prominent when the interfaces were perpendicular to the axis of the main magnetic field (Z axis). The regions of increased brightness obscured normal orbital structures but were not associated with alterations in the geometry of these structures. Changes in orientation of the interfaces with respect to the Z axis, both in the phantoms and normal volunteer, reproduced the asymmetry of fat suppression failure seen in clinical cases. The relationship of size of the artifact to change in orientation was non-linear. The artifact was not seen on STIR images. We concluded that failure of FATSAT fat suppression may mimic orbital disease, particularly if asymmetric. As predicted by the Maxwell electromagnetism equation, slight variations in orientation of the fat-air interface to the Z axis may produce large asymmetries in fat suppression failure in the orbit. Confirmation may require either comparison with additional pulse sequences [T1-weighted spin echo (T1W SE) or STIR] or repositioning the patient's head to check for persistence of the finding with varying orientations.

Entities:  

Mesh:

Year:  1997        PMID: 9093955

Source DB:  PubMed          Journal:  J Neuroophthalmol        ISSN: 1070-8022            Impact factor:   3.042


  5 in total

1.  MRI artifact masquerading as orbital disease.

Authors:  B A Brown; C E Swallow; A S Eiseman
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Contrast-enhanced MR myelography in spontaneous intracranial hypotension: description of an artefact imitating CSF leakage.

Authors:  Elke Hattingen; Richard DuMesnil; Ulrich Pilatus; Andreas Raabe; Timo Kahles; Jürgen Beck
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

3.  Intravenous Line Phase-Wrap Artifact at Bilateral Axial 3-T Breast MRI: Identification, Analysis, and Solution.

Authors:  Einat Slonimsky; Yusef Azraq; John M Gomori; Susan Fisch; Tal Arazi Kleinman; Tamar Sella
Journal:  Radiol Imaging Cancer       Date:  2020-11-06

4.  Imaging of skull base tumours.

Authors:  Stefanie Catherine Thust; Tarek Yousry
Journal:  Rep Pract Oncol Radiother       Date:  2016-02-02

5.  Usefulness of two-point Dixon T2-weighted imaging in thyroid-associated ophthalmopathy: comparison with conventional fat saturation imaging in fat suppression quality and staging performance.

Authors:  Lu Chen; Hao Hu; Huan-Huan Chen; Wen Chen; Qian Wu; Fei-Yun Wu; Xiao-Quan Xu
Journal:  Br J Radiol       Date:  2020-12-22       Impact factor: 3.039

  5 in total