Literature DB >> 9090599

Peripheral nerve stimulation in a whole-body echo-planar imaging system.

J C Ehrhardt1, C S Lin, V A Magnotta, D J Fisher, W T Yuh.   

Abstract

Echo-planar techniques in MRI use a rapidly oscillating frequency-encoding gradient with the potential to produce peripheral nerve stimulation. To evaluate the incidence, type, and location of stimulation in a commercial whole-body scanner, we studied two groups: (a) 173 consecutive individuals scanned by echo-planar imaging for other purposes and (b) seven subjects who were scanned with an extensive set of 36 echo-planar sequences (with prompting after each scan to report any peripheral nerve stimulation) to test the effects of various parameters. Although only 5% of group A reported symptoms of peripheral nerve stimulation, all in group B experienced some type of stimulation, dependent primarily on direction of the oscillating gradient and location of the body within the gradient coil. Maximum stimulation typically occurred 30 to 40 cm from isocenter in the region of maximum dB/dt. Generally, y gradients produced truncal stimulation, and x gradients produced stimulation in the head. When hands were clasped over the abdomen, a tingling in the hands occasionally was felt. Patients should be instructed to keep their hands apart.

Entities:  

Mesh:

Year:  1997        PMID: 9090599     DOI: 10.1002/jmri.1880070226

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

1.  The modular (twin) gradient coil--high resolution, high contrast, diffusion weighted EPI at 1.0 Tesla.

Authors:  P R Harvey
Journal:  MAGMA       Date:  1999-03       Impact factor: 2.310

Review 2.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

Review 3.  Implementation of a comprehensive MR safety course for medical students.

Authors:  Steffen Sammet; Christina L Sammet
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

4.  Controlled E-field gradient coils.

Authors:  P Mansfield; R M Bowley; B Haywood
Journal:  MAGMA       Date:  2003-10-31       Impact factor: 2.310

5.  Improved B0 -distortion correction in diffusion MRI using interlaced q-space sampling and constrained reconstruction.

Authors:  Chitresh Bhushan; Anand A Joshi; Richard M Leahy; Justin P Haldar
Journal:  Magn Reson Med       Date:  2013-11-11       Impact factor: 4.668

Review 6.  Magnetic resonance safety.

Authors:  Steffen Sammet
Journal:  Abdom Radiol (NY)       Date:  2016-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.