A low dielectric constant customized phantom design to measure RF coil nonuniformity.

P S Tofts1, G J Barker, T L Dean, H Gallagher, A P Gregory, R N Clarke.   

Abstract

The selection of a suitable low dielectric constant liquid for radiofrequency coil nonuniformity measurements is described. Measurements of dielectric constant (relative permittivity) were made on a range of candidate liquids. After excluding liquids that were too inflammable or too viscous, Esso Bayol 82 oil (dielectric constant epsilon' = 2.37) was chosen. At 1.5 T, a 27 cm diameter cylindrical phantom (test object) filled with Bayol 82 has a maximum nonuniformity of 1.9% arising from radiofrequency standing waves. The maximum diameter cylinder that can be used without the nonuniformity exceeding 2% is given for a range of liquids and field strengths. The construction of customized containers that fit closely inside a radiofrequency head coil from glass fiber reinforced resin ("fiberglass") is described. Thermal expansion of the liquid takes place without a rise in the internal pressure in the container.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9084027     DOI: 10.1016/s0730-725x(96)00220-2

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  Impact of field strength and RF excitation on abdominal diffusion-weighted magnetic resonance imaging.

Authors:  Philipp Riffel; Raghuram K Rao; Stefan Haneder; Mathias Meyer; Stefan O Schoenberg; Henrik J Michaely
Journal:  World J Radiol       Date:  2013-09-28

2.  An anatomically realistic temperature phantom for radiofrequency heating measurements.

Authors:  Nadine N Graedel; Jonathan R Polimeni; Bastien Guerin; Borjan Gagoski; Giorgio Bonmassar; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

3.  Flip angle mapping with the accelerated 3D look-locker sequence.

Authors:  Trevor Wade; Charles A McKenzie; Brian K Rutt
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

4.  Implementation of dual-source RF excitation in 3 T MR-scanners allows for nearly identical ADC values compared to 1.5 T MR scanners in the abdomen.

Authors:  Raghuram K Rao; Philipp Riffel; Mathias Meyer; Paul J Kettnaker; Andreas Lemke; Stefan Haneder; Stefan O Schoenberg; Henrik J Michaely
Journal:  PLoS One       Date:  2012-02-29       Impact factor: 3.240

5.  A medical device-grade T1 and ECV phantom for global T1 mapping quality assurance-the T1 Mapping and ECV Standardization in cardiovascular magnetic resonance (T1MES) program.

Authors:  Gabriella Captur; Peter Gatehouse; Kathryn E Keenan; Friso G Heslinga; Ruediger Bruehl; Marcel Prothmann; Martin J Graves; Richard J Eames; Camilla Torlasco; Giulia Benedetti; Jacqueline Donovan; Bernd Ittermann; Redha Boubertakh; Andrew Bathgate; Celine Royet; Wenjie Pang; Reza Nezafat; Michael Salerno; Peter Kellman; James C Moon
Journal:  J Cardiovasc Magn Reson       Date:  2016-09-22       Impact factor: 5.364

6.  9.4 T small animal MRI using clinical components for direct translational studies.

Authors:  Jörg Felder; A Avdo Celik; Chang-Hoon Choi; Stefan Schwan; N Jon Shah
Journal:  J Transl Med       Date:  2017-12-28       Impact factor: 5.531

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.