Literature DB >> 19399543

The effect of elbow joint centre displacement on force generation and neural excitation.

Emer P Doheny1, Madeleine M Lowery, Mark J O'Malley, David P Fitzpatrick.   

Abstract

Joint centre displacement may occur following total elbow replacement due to aseptic loosening or surgical misalignment, and has been linked to implant failure. In this study, the effects of joint centre displacement were examined using a neuromusculoskeletal model of the elbow joint. Isometric contractions were simulated at a range of joint angles during elbow flexion and extension. Displacement of the joint centre affected the force-generating capacity about the joint, due to changes in both muscle lengths and moment arms. The magnitude and direction of the maximum joint reaction force were also altered, potentially contributing to aseptic loosening and compromising joint stability. The relationship between force generated and the level of neural excitation to the elbow flexor and extensor muscles was also affected, suggesting that altered neural control patterns could be required following joint centre displacement.

Mesh:

Year:  2009        PMID: 19399543     DOI: 10.1007/s11517-009-0488-2

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  39 in total

1.  Survivorship and radiological analysis of the standard Souter-Strathclyde total elbow arthroplasty.

Authors:  I A Trail; D Nuttall; J K Stanley
Journal:  J Bone Joint Surg Br       Date:  1999-01

2.  Experimental investigation of reaction forces at the glenohumeral joint during active abduction.

Authors:  M Apreleva; I M Parsons; J J Warner; F H Fu; S L Woo
Journal:  J Shoulder Elbow Surg       Date:  2000 Sep-Oct       Impact factor: 3.019

3.  Contribution of stretch reflexes to locomotor control: a modeling study.

Authors:  S Yakovenko; V Gritsenko; A Prochazka
Journal:  Biol Cybern       Date:  2004-01-20       Impact factor: 2.086

4.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors.

Authors:  Andrea Giovanni Cutti; Andrea Giovanardi; Laura Rocchi; Angelo Davalli; Rinaldo Sacchetti
Journal:  Med Biol Eng Comput       Date:  2007-12-18       Impact factor: 2.602

5.  Superior displacement of the hip in total joint replacement: effects of prosthetic neck length, neck-stem angle, and anteversion angle on the moment-generating capacity of the muscles.

Authors:  S L Delp; A V Komattu; R L Wixson
Journal:  J Orthop Res       Date:  1994-11       Impact factor: 3.494

6.  How superior placement of the joint center in hip arthroplasty affects the abductor muscles.

Authors:  S L Delp; R L Wixson; A V Komattu; J H Kocmond
Journal:  Clin Orthop Relat Res       Date:  1996-07       Impact factor: 4.176

7.  Kinematics of the elbow.

Authors:  J T London
Journal:  J Bone Joint Surg Am       Date:  1981-04       Impact factor: 5.284

8.  Souter-Strathclyde total elbow arthroplasty.

Authors:  P Rozing
Journal:  J Bone Joint Surg Br       Date:  2000-11

9.  A neuromusculoskeletal model to simulate the constant angular velocity elbow extension test of spasticity.

Authors:  Terry K K Koo; Arthur F T Mak
Journal:  Med Eng Phys       Date:  2006-01       Impact factor: 2.242

10.  Models of ensemble firing of muscle spindle afferents recorded during normal locomotion in cats.

Authors:  A Prochazka; M Gorassini
Journal:  J Physiol       Date:  1998-02-15       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.