Literature DB >> 9065063

The Wagner revision stem for severe osteolysis. 31 hips followed for 1.5-5 years.

K Kolstad1, G Adalberth, H Mallmin, J Milbrink, B Sahlstedt.   

Abstract

We used the Wagner (1989) method in 31 hip revisions because of loosening with pronounced scalloping, which made a conventional revision unsuitable. The radiographs showed that within a few months new bone developed in the defects. In 5 cases, a new revision was necessary at an early stage, because of dislocation and/or subsidence. At follow-up after 3 (1.5-5) years, 21 of the remaining 26 hips were pain-free and 23 had almost full range of motion.

Entities:  

Mesh:

Year:  1996        PMID: 9065063     DOI: 10.3109/17453679608997752

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  15 in total

1.  Giants of Orthopaedic Surgery: Professor Heinz Wagner.

Authors:  Michael B Millis
Journal:  Clin Orthop Relat Res       Date:  2017-05-22       Impact factor: 4.176

2.  Revision total hip arthroplasty using a cementless tapered revision stem in patients with a mean age of 82 years.

Authors:  Daniel Neumann; Lothar Dueckelmann; Christoph Thaler; Ulrich Dorn
Journal:  Int Orthop       Date:  2011-10-26       Impact factor: 3.075

3.  Modular femoral stems for revision total hip arthroplasty.

Authors:  Camilo Restrepo; Magdalena Mashadi; Javad Parvizi; Matthew S Austin; William J Hozack
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  Stem and osteotomy length are critical for success of the transfemoral approach and cementless stem revision.

Authors:  Daniel F A de Menezes; Pierre Le Béguec; Hans-Peter Sieber; Mathias Goldschild
Journal:  Clin Orthop Relat Res       Date:  2011-08-06       Impact factor: 4.176

5.  [Modular noncemented femoral stem system in revision total hip arthroplasty].

Authors:  M D Schofer; T Efe; T J Heyse; N Timmesfeld; R Velte; F Hinrichs; J Schmitt
Journal:  Orthopade       Date:  2010-02       Impact factor: 1.087

6.  Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs.

Authors:  Nemandra A Sandiford; Donald S Garbuz; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2016-09-26       Impact factor: 4.176

7.  High medium-term survival of Zweymüller SLR-plus stem used in femoral revision.

Authors:  Panagiotis Korovessis; Thomas Repantis
Journal:  Clin Orthop Relat Res       Date:  2009-03-03       Impact factor: 4.176

8.  Single 3° tapered fluted femoral stems demonstrate low subsidence at mid-term follow-up in severe bony deficiency.

Authors:  Albert W T Ngu; Fiachra E Rowan; Alberto V Carli; Fares S Haddad
Journal:  Ann Transl Med       Date:  2019-12

9.  Stem modularity alone is not effective in reducing dislocation rate in hip revision surgery.

Authors:  Dario Regis; Andrea Sandri; Pietro Bartolozzi
Journal:  J Orthop Traumatol       Date:  2009-11-18

10.  Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant.

Authors:  Matthias D Wimmer; Thomas M Randau; Moritz C Deml; Rudolf Ascherl; Ulrich Nöth; Raimund Forst; Nadine Gravius; Dieter Wirtz; Sascha Gravius
Journal:  BMC Musculoskelet Disord       Date:  2013-01-11       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.