Literature DB >> 9062140

Color Doppler and duplex flow analysis for classification of breast lesions.

H Madjar1, W Sauerbrei, H J Prömpeler, R Wolfarth, H Gufler.   

Abstract

The purpose of this study was to evaluate the differences of blood supply in benign and malignant breast tumors by color Doppler flow measurements. The study included 471 patients, 133 with carcinomas, 325 with benign breast lesions, and 13 with mastitis. An ATL UM9/HDI was used with an electronic 10-MHz linear array broadband transducer. The following flow data were analyzed: Presence of vascularity; number of tumor arteries; the mean, minimum, maximum RI index, and AB ratio; the mean, minimum, and maximum peak systolic flow velocity and the sum of all peak systolic flow velocities in each tumor. In all cancers and in most benign pathologies vascularity was found. Highly significant differences between benign and malignant were found for all quantitative flow data such as number of tumor arteries and blood flow velocity (P < 0.0001). Flow profiles analyzed by RI index and AB ratio showed a trend for increased flow resistance in malignancies. However, due to the wide overlap between benign and malignant, indices did not allow a sufficient differentiation. The study showed that standardization of the Doppler examination technique and equipment parameters is essential for vascularity assessment of tumors.

Entities:  

Mesh:

Year:  1997        PMID: 9062140     DOI: 10.1006/gyno.1996.4585

Source DB:  PubMed          Journal:  Gynecol Oncol        ISSN: 0090-8258            Impact factor:   5.482


  8 in total

1.  Diagnostic efficiency of sestamibi gammagraphy and Doppler sonography in the preoperative assessment of breast lesions.

Authors:  Antonio Piñero; Pedro José Galindo; Julián Illana; Francisco Nicolás; Manuel Reus; María Dolores Hernández; Isidro Durán; Manuel Canteras; Pascual Parrilla
Journal:  Clin Transl Oncol       Date:  2006-02       Impact factor: 3.405

2.  Alignment of sources and detectors on breast surface for noncontact diffuse correlation tomography of breast tumors.

Authors:  Chong Huang; Yu Lin; Lian He; Daniel Irwin; Margaret M Szabunio; Guoqiang Yu
Journal:  Appl Opt       Date:  2015-10-10       Impact factor: 1.980

Review 3.  Near-infrared diffuse correlation spectroscopy in cancer diagnosis and therapy monitoring.

Authors:  Guoqiang Yu
Journal:  J Biomed Opt       Date:  2012-01       Impact factor: 3.170

4.  Correlation between Blood Flow Signal of Color Flow Imaging and Nottingham Prognostic Index in Patients with Breast Carcinoma.

Authors:  Zhi-Yong Shen; Bing Hu; Ming-Feng Wu
Journal:  Breast Care (Basel)       Date:  2012-04-24       Impact factor: 2.860

5.  [Breast cancer. Sonography and magnetic resonance mammography].

Authors:  S Delorme
Journal:  Radiologe       Date:  2004-06       Impact factor: 0.635

6.  Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours.

Authors:  D- A Clevert; E M Jung; K-P Jungius; K Ertan; R Kubale
Journal:  Eur Radiol       Date:  2006-07-06       Impact factor: 5.315

7.  The contribution of three-dimensional power Doppler imaging in the preoperative assessment of breast tumors: a preliminary report.

Authors:  K Kalmantis; C Dimitrakakis; Ch Koumpis; A Tsigginou; N Papantoniou; S Mesogitis; A Antsaklis
Journal:  Obstet Gynecol Int       Date:  2009

8.  Optically measured microvascular blood flow contrast of malignant breast tumors.

Authors:  Regine Choe; Mary E Putt; Peter M Carlile; Turgut Durduran; Joseph M Giammarco; David R Busch; Ki Won Jung; Brian J Czerniecki; Julia Tchou; Michael D Feldman; Carolyn Mies; Mark A Rosen; Mitchell D Schnall; Angela DeMichele; Arjun G Yodh
Journal:  PLoS One       Date:  2014-06-26       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.