Parallel transmit optimized 3D composite adiabatic spectral-spatial pulse for spectroscopy.

Xiaoxuan He1, Edward J Auerbach1, Michael Garwood1, Naoharu Kobayashi1, Xiaoping Wu1, Gregory J Metzger1.   

Abstract

PURPOSE: To develop a 3D composite adiabatic spectral-spatial pulse for refocusing in spin-echo spectroscopy acquisitions and to compare its performance against standard acquisition methods.
METHODS: A 3D composite adiabatic pulse was designed by modulating a train of parallel transmit-optimized 2D subpulses with an adiabatic envelope. The spatial and spectral profiles were simulated and validated by experiments to demonstrate the feasibility of the design in both single and double spin-echo spectroscopy acquisitions. Phantom and in vivo studies were performed to evaluate the pulse performance and compared with semi-LASER with respect to localization performance, sequence timing, signal suppression, and specific absorption rate.
RESULTS: Simultaneous 2D spatial localization with water and lipid suppression was achieved with the designed refocusing pulse, allowing high-quality spectra to be acquired with shorter minimum TE/TR, reduced SAR, as well as adaptation to spatially varying B0 and B 1 + field inhomogeneities in both prostate and brain studies.
CONCLUSION: The proposed composite pulse can serve as a more SAR efficient alternative to conventional localization methods such as semi-LASER at ultrahigh field for spin echo-based spectroscopy studies. Subpulse parallel-transmit optimization provides the flexibility to manage the tradeoff among multiple design criteria to accommodate different field strengths and applications.
© 2021 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  RF pulse design; magnetic resonance spectroscopy; parallel transmission; ultrahigh-field imaging

Mesh:

Year:  2021        PMID: 33497006      PMCID: PMC8545499          DOI: 10.1002/mrm.28682

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   3.737


  57 in total

1.  Mapping brain metabolites using a double echo-filter metabolite imaging (DEFMI) technique.

Authors:  W Chen; J Hu
Journal:  J Magn Reson       Date:  1999-10       Impact factor: 2.229

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  Selective excitation of two-dimensional arbitrarily shaped voxels with parallel excitation in spectroscopy.

Authors:  Jeff Snyder; Martin Haas; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2011-06-30       Impact factor: 4.668

4.  Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy.

Authors:  R J Ordidge; M Wylezinska; J W Hugg; E Butterworth; F Franconi
Journal:  Magn Reson Med       Date:  1996-10       Impact factor: 4.668

5.  Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T.

Authors:  Vincent Gras; Franck Mauconduit; Alexandre Vignaud; Alexis Amadon; Denis Le Bihan; Tony Stöcker; Nicolas Boulant
Journal:  Magn Reson Med       Date:  2017-11-29       Impact factor: 4.668

6.  Designing 3D selective adiabatic radiofrequency pulses with single and parallel transmission.

Authors:  Albert Jang; Xiaoping Wu; Edward J Auerbach; Michael Garwood
Journal:  Magn Reson Med       Date:  2017-05-12       Impact factor: 4.668

7.  Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging.

Authors:  Jun Ma; Carrie Wismans; Zhipeng Cao; Dennis W J Klomp; Jannie P Wijnen; William A Grissom
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

8.  Fast large-tip-angle multidimensional and parallel RF pulse design in MRI.

Authors:  William A Grissom; Dan Xu; Adam B Kerr; Jeffrey A Fessler; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048

9.  Interleaved narrow-band PRESS sequence with adiabatic spatial-spectral refocusing pulses for 1H MRSI at 7T.

Authors:  Priti Balchandani; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

Review 10.  Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions.

Authors:  M Arcan Erturk; Xiufeng Li; Pierre-Fancois Van de Moortele; Kamil Ugurbil; Gregory J Metzger
Journal:  Top Magn Reson Imaging       Date:  2019-06
View more
  1 in total

Review 1.  Ultra-high-field MR in Prostate cancer: Feasibility and Potential.

Authors:  Carlijn J A Tenbergen; Gregory J Metzger; Tom W J Scheenen
Journal:  MAGMA       Date:  2022-05-17       Impact factor: 2.533

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.