Literature DB >> 9054897

Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study.

E Vigneault1, J Pouliot, J Laverdière, J Roy, M Dorion.   

Abstract

PURPOSE: This study was designed to assess daily prostatic apex motion relative to pelvic bone structures during megavoltage irradiation. METHODS AND MATERIALS: Radioopaque markers were implanted under ultrasound guidance near the prostatic apex of 11 patients with localized prostatic carcinoma. Patients were subsequently treated with a four field-box technique at a beam energy of 23 MV. During treatment, on-line images were obtained with an electronic portal imaging device (EPID). The marker was easily identified, even on unprocessed images, and the distance between the marker and a bony landmark was measured. Timelapse movies were also reviewed. After the completion of treatment, a transrectal ultrasound examination was performed in 8 of 11 patients, to verify the position of the marker.
RESULTS: We acquired over 900 digital portal images and analyzed posterioanterior and right lateral views. The quality of portal images obtained with megavoltage irradiation was good. It was possible to evaluate pelvic bone structures even without image histogram equalization. Moreover, the radioopaque marker was easily visible on every online portal image. The review of timelapse movies showed important interfraction motion of the marker while bone structures remained stable. We measured the position of the marker for each fraction. Marker displacements up to 1.6 cm were measured between 2 consecutive days of treatment. Important marker motions were predominantly in the posteroanterior and cephalocaudal directions. In eight patients, we verified the position of the marker relative to the prostatic apex with ultrasound at the end of the treatments. The marker remained in the trapezoid zone. Intratreatment images reviewed in two cases showed no-change in marker position. Our results, obtained during the treatment courses, indicate similar or larger prostate motions than previously observed in studies that used intertreatment x-ray films and CT images. Marker implantation under transrectal ultrasound was well tolerated.
CONCLUSIONS: Radioopaque marker and the use of electronic portal imaging give a direct evaluation of prostatic motion during radiation treatment. As suggested in previous studies the motions observed are predominantly in the posteroanterior and cephalocaudal directions. Therefore, prostate motion during treatment is important and must be considered especially when using conformal therapy.

Entities:  

Mesh:

Year:  1997        PMID: 9054897     DOI: 10.1016/s0360-3016(96)00341-0

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  29 in total

1.  Comparisons of the impact of systematic uncertainties in patient setup and prostate motion on doses to the target among different plans for definitive external-beam radiotherapy for prostate cancer.

Authors:  Su Yu Zhu; Takashi Mizowaki; Yoshiki Norihisa; Kenji Takayama; Yasushi Nagata; Masahiro Hiraoka
Journal:  Int J Clin Oncol       Date:  2008-02-29       Impact factor: 3.402

Review 2.  Current status of intensity-modulated radiation therapy (IMRT).

Authors:  Kazuo Hatano; Hitoshi Araki; Mitsuhiro Sakai; Takashi Kodama; Naoki Tohyama; Tohru Kawachi; Masaharu Imazeki; Takayuki Shimizu; Tsutomu Iwase; Minoru Shinozuka; Hideyo Ishigaki
Journal:  Int J Clin Oncol       Date:  2007-12-21       Impact factor: 3.402

3.  The observed variance between predicted and measured radiation dose in breast and prostate patients utilizing an in vivo dosimeter.

Authors:  Charles W Scarantino; Bradley R Prestidge; Mitchel S Anscher; Carolyn R Ferree; William T Kearns; Robert D Black; Natasha G Bolick; Gloria P Beyer
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-10-01       Impact factor: 7.038

4.  CTV to PTV margins for prostate irradiation. Three-dimensional quantitative assessment of interfraction uncertainties using portal imaging and serial CT scans.

Authors:  Luis A Pérez-Romasanta; Eva Lozano-Martín; Joaquín Velasco-Jiménez; Fermín Mendicote-León; Miguel Sanz-Martín; Javier Torres-Donaire; Carmen Carrascosa-Fernández; Juan Carlos Zapata-Jimínez; Jacinto Arjona-Gutiérrez; Antonio Gil-Agudo
Journal:  Clin Transl Oncol       Date:  2009-09       Impact factor: 3.405

5.  [Significance of a rectal balloon as internal immobilization device in conformal radiotherapy of prostatic carcinoma].

Authors:  N Gerstner; S Wachter; D Dorner; G Goldner; A Colotto; R Pötter
Journal:  Strahlenther Onkol       Date:  1999-05       Impact factor: 3.621

6.  A survey of image-guided radiation therapy use in the United States.

Authors:  Daniel R Simpson; Joshua D Lawson; Sameer K Nath; Brent S Rose; Arno J Mundt; Loren K Mell
Journal:  Cancer       Date:  2010-08-15       Impact factor: 6.860

7.  High-dose-rate brachytherapy combined with long-term hormonal therapy for high-risk prostate cancer: results of a retrospective analysis.

Authors:  Ryoong-Jin Oh; Yasuo Yoshioka; Eiichi Tanaka; Hiroya Shiomi; Iori Sumida; Fumiaki Isohashi; Osamu Suzuki; Koji Konishi; Yoshifumi Kawaguchi; Satoaki Nakamura; Masahiro Kato; Takehiro Inoue
Journal:  Radiat Med       Date:  2006-01

8.  Is a 3-mm intrafractional margin sufficient for daily image-guided intensity-modulated radiation therapy of prostate cancer?

Authors:  Adam D Melancon; Jennifer C O'Daniel; Lifei Zhang; Rajat J Kudchadker; Deborah A Kuban; Andrew K Lee; Rex M Cheung; Renaud de Crevoisier; Susan L Tucker; Wayne D Newhauser; Radhe Mohan; Lei Dong
Journal:  Radiother Oncol       Date:  2007-09-24       Impact factor: 6.280

9.  A strategy for the use of image-guided radiotherapy (IGRT) on linear accelerators and its impact on treatment margins for prostate cancer patients.

Authors:  Olaf Nairz; Florian Merz; Heinz Deutschmann; Peter Kopp; Helmut Schöller; Franz Zehentmayr; Karl Wurstbauer; Gerhard Kametriser; Felix Sedlmayer
Journal:  Strahlenther Onkol       Date:  2008-12-24       Impact factor: 3.621

10.  Positional reproducibility and effects of a rectal balloon in prostate cancer radiotherapy.

Authors:  Jae Ho Cho; Chang-Geol Lee; Dae Ryong Kang; Jooho Kim; Sangkyu Lee; Chang-Ok Suh; Jinsil Seong; Yang Gun Suh; Ikjae Lee; Gwi Eon Kim
Journal:  J Korean Med Sci       Date:  2009-09-24       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.