Literature DB >> 9051527

Scanning electron microscopic analysis of foldable acrylic and hydrogel intraocular lenses.

T Kohnen1, G Magdowski, D D Koch.   

Abstract

OBJECTIVE: To analyze the surface quality of foldable acrylic and hydrogel intraocular lenses (IOLs).
SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, and Institute of Anatomy and Cellular Biology, University of Giessen, Germany.
METHODS: We studied eight foldable IOL models with optics made of six different acrylate/methacrylate polymers: Acrylens ACR360 (loptex), AcrySof MA60BM (Alcon), MemoryLens U940A (Mentor), 92S and 92C (Morcher), Hydroview H60M (Storz), HydroSof SH30BC (Alcon), and ISH66 (Corneal). Four IOLs of each design were examined. Light and scanning electron microscopy were performed before and after IOL folding with forceps.
RESULTS: All IOL models had excellent optic and haptic surfaces. The haptic-optic junctions revealed minimal empty spaces or irregularities in three of the five three-piece IOLs and smooth surfaces in all one-piece IOLs. Minimal surface alterations and superficial defects caused by folding were detectable in the two acrylate (acrylic) IOLs (loptex ACR360, Alcon MA60BM) with low water content.
CONCLUSION: Intraocular lenses of acrylate/methacrylate polymers had excellent surface quality. The acrylic IOLs were vulnerable to mild folding or forceps defects; however, these were less marked than those previously noted with poly(methyl methacrylate) IOLs.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9051527     DOI: 10.1016/s0886-3350(96)80095-2

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses.

Authors:  Guy Kleinmann; David J Apple
Journal:  Br J Ophthalmol       Date:  2006-11-29       Impact factor: 4.638

2.  Linear deposits on the surfaces of intraocular lenses implanted through a hexagonal cartridge which mimic scratches/cracks on the lenses.

Authors:  G Kleinmann; A L Marcovich; D J Apple; N Mamalis
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

3.  [Microincision intraocular lens with plate haptic design. Evaluation of rotational stability and centering of a microincision intraocular lens with plate haptic design in 12-19 months of follow-up].

Authors:  W Wehner
Journal:  Ophthalmologe       Date:  2007-05       Impact factor: 1.059

4.  A practical and easy surgical technique for recovery of an incarcerated haptic.

Authors:  Yusuf Koçluk; Emine Alyamaç Sukgen; Burcu Kasım; Oğuzhan Saygılı
Journal:  Int Ophthalmol       Date:  2018-11-22       Impact factor: 2.031

Review 5.  [The basics of refractive lens exchange].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

6.  Hydrophilic Acrylic versus PMMA Intraocular Lens Implantation in Pediatric Cataract Surgery.

Authors:  Mahmoud-Reza Panahi-Bazaz; Mitra Zamani; Bijan Abazar
Journal:  J Ophthalmic Vis Res       Date:  2009-10

7.  Descemet's tear due to injector cartridge tip deformity.

Authors:  Partha Biswas; Subhrangshu Sengupta; Ajoy Paul; Lav Kochgaway; Sayantan Biswas
Journal:  Indian J Ophthalmol       Date:  2012 May-Jun       Impact factor: 1.848

  7 in total