Literature DB >> 9051523

Visual properties of the foldable Array multifocal intraocular lens.

H Weghaupt1, S Pieh, C Skorpik.   

Abstract

PURPOSE: To evaluate visual acuity, depth of focus, contrast sensitivity, and glare disability in eyes with an Array SSM 26-NB three-piece, five-zone multifocal intraocular lens (IOL).
SETTING: University Eye Clinic, Vienna, Austria.
METHOD: Fourteen eyes with an AMO Array IOL were evaluated for uncorrected and best corrected distance and near visual acuity. The reading distance produced by the near focus of the lens was varied with convex glasses of less power. Reading at distance focus was evaluated by adding +3.50 diopters (D) to the distance correction. Depth of focus was measured from -3.00 to +6.00 D. Contrast sensitivity and glare disability were also measured using the Brightness Acuity Tester with stationary sinusoidal gratings at 0.5, 1, 3, 6, 11.4, and 22.8 cycles/degree.
RESULTS: Mean uncorrected distance acuity (Snellen) was 0.79 +/- 0.17 (SD), which increased to 0.94 +/- 0.14 with best correction. Near acuity was J2.75 +/- 1.35 and J2.59 +/- 1.10, respectively. When near focus was tested for reading distance, a mean of +0.54 +/- 0.02 D was accepted for improvement of near vision of J1.71 +/- 0.94. Near acuity with a distance focus addition of +3.50 D was J1.08 +/- 0.28. Contrast sensitivity and glare disability were lower than in 13 eyes with a monofocal poly(methyl methacrylate) IOL and 16 normal phakic eyes.
CONCLUSIONS: Eyes with the Array IOL had full distance function. Reading performance could be improved with a near focus of more than +3.50 D. Full near vision could be achieved with the distance focus and conventional reading glasses. Depth of focus was sufficient but visual acuity was limited at intermediate and near distance. Although contrast sensitivity was relatively low, it was not beyond the reference range.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9051523     DOI: 10.1016/s0886-3350(96)80091-5

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Tritan colour contrast sensitivity function in refractive multifocal intraocular lenses.

Authors:  S Pieh; G Hanselmayer; B Lackner; P Marvan; A Grechenig; H Weghaupt; C Vass; C Skorpik
Journal:  Br J Ophthalmol       Date:  2001-07       Impact factor: 4.638

2.  Halo size under distance and near conditions in refractive multifocal intraocular lenses.

Authors:  S Pieh; B Lackner; G Hanselmayer; R Zöhrer; M Sticker; H Weghaupt; A Fercher; C Skorpik
Journal:  Br J Ophthalmol       Date:  2001-07       Impact factor: 4.638

3.  Secondary multifocal intraocular lens implantation: A novel management strategy for white cataracts.

Authors:  Jiawen Ling; Yiyong Qian; Peirong Lu
Journal:  SAGE Open Med Case Rep       Date:  2018-01-04

4.  Comparison of visual performance of multifocal intraocular lenses with same material monofocal intraocular lenses.

Authors:  Tomofusa Yamauchi; Hitoshi Tabuchi; Kosuke Takase; Hideharu Ohsugi; Zaigen Ohara; Yoshiaki Kiuchi
Journal:  PLoS One       Date:  2013-06-28       Impact factor: 3.240

5.  Comparison of visual performance between monofocal and multifocal intraocular lenses of the same material and basic design.

Authors:  Hirotaka Tanabe; Hitoshi Tabuchi; Tomohiro Shojo; Tomofusa Yamauchi; Kosuke Takase
Journal:  Sci Rep       Date:  2020-09-23       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.