Literature DB >> 9051227

Evaluation of instruments for noninvasive blood pressure monitoring of the wrist.

N S Latman1, A Latman.   

Abstract

Commercially-available electronic, digital, oscillometric instruments for monitoring wrist blood pressure (BP) are intended for use by the general public in home health care. The purpose of this study was to evaluate the performance of these instruments for accuracy, reliability, and failure rate. Blood pressure and heart rate (HR) measurements from the new wrist instruments were compared with sequentially recorded BPs determined by auscultation of the branchial artery and HRs determined by palpation of the radial artery. Accuracy and reliability were determined using linear regression, correlation coefficients, and standard error of the estimates. The wrist BP instruments were very easy to use on a variety of individuals. No failure to record a BP or HR was observed. The wrist devices appeared less accurate than the standard, branchial-artery, ausculatory method. The wrist BP instruments tended to overestimate hypotensive and significantly under estimate hypertensive BPs. The wrist device's HR accuracy and reliability appeared to approximate that of the standard method.

Entities:  

Mesh:

Year:  1997        PMID: 9051227

Source DB:  PubMed          Journal:  Biomed Instrum Technol        ISSN: 0899-8205


  5 in total

1.  Nondipping heart rate and associated factors in patients with chronic kidney disease.

Authors:  Zeynep Biyik; Yasemin Coskun Yavuz; Lütfullah Altintepe; Gulperi Celik; Ibrahim Guney; Sevıl Fısekcı Oktar
Journal:  Clin Exp Nephrol       Date:  2019-09-03       Impact factor: 2.801

2.  Discrepancy of blood pressure between the brachial artery and radial artery.

Authors:  Wen-Yuan Li; Xiao-Hai Wang; Li-Chong Lu; Hao Li
Journal:  World J Emerg Med       Date:  2013

3.  Does "hidden undercuffing" occur among obese patients? Effect of arm sizes and other predictors of the difference between wrist and upper arm blood pressures.

Authors:  Hardik Doshi; Alan B Weder; Robert L Bard; Robert D Brook
Journal:  J Clin Hypertens (Greenwich)       Date:  2010-02-01       Impact factor: 3.738

4.  Nocturnal pulse rate correlated with ambulatory blood pressure and target organ damage in patients with chronic kidney disease.

Authors:  Jun Zhang; Ruowei Wen; Jinmei Yin; Ye Zhu; Lin Lin; Zengchun Ye; Hui Peng; Cheng Wang; Tanqi Lou
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-12-31       Impact factor: 3.738

5.  Adherence to blood pressure measurement guidelines in long-term care facilities: A cross sectional study.

Authors:  Sachiko Ozone; Mikiya Sato; Ayumi Takayashiki; Naoto Sakamoto; Hisashi Yoshimoto; Tetsuhiro Maeno
Journal:  J Gen Fam Med       Date:  2018-03-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.