Literature DB >> 25215136

Discrepancy of blood pressure between the brachial artery and radial artery.

Wen-Yuan Li1, Xiao-Hai Wang2, Li-Chong Lu3, Hao Li4.   

Abstract

BACKGROUND: In this study, we attempted to find the relations between blood pressure (BP) measured on the brachial artery (bBP) and BP assessed on the radial artery (rBP) in the right arm.
METHODS: Three hundred and fifteen patients were enrolled in this study. Those who had peripheral vascular disease, wounds of arm skin or subcutaneous tissue infection were excluded. After a 15-minute equilibration and stabilization period after inducation of anesthesia, three bBP and rBP records were obtained sequentially using an oscillometric device with an adult cuff and infant cuff, respectively. Order for each BP was randomized.
RESULTS: The bBP was significantly lower than the rBP (P<0.05). The difference between the two values varied from 13 to 18 mmHg in systolic BP (SBP), diastolic BP (DBP) and mean blood pressure (MAP) respectively. And the rBP was positively correlated with the bBP (r=0.872, 0.754, 0.765; P<0.001, <0.001, <0.001; SBP, DBP, MAP, respectively).
CONCLUSION: The bBP value can be evaluated by the noninvasive measurements of rBP using an appropriate cuff in clinical practice.

Entities:  

Keywords:  Blood pressure; Brachial artery; Correlation; Linear regression; Radial artery

Year:  2013        PMID: 25215136      PMCID: PMC4129906          DOI: 10.5847/wjem.j.issn.1920-8642.2013.04.010

Source DB:  PubMed          Journal:  World J Emerg Med        ISSN: 1920-8642


  14 in total

Review 1.  Evidence based treatment of hypertension. Measurement of blood pressure: an evidence based review.

Authors:  F A McAlister; S E Straus
Journal:  BMJ       Date:  2001-04-14

2.  Blood pressure measuring devices: recommendations of the European Society of Hypertension.

Authors:  E O'Brien; B Waeber; G Parati; J Staessen; M G Myers
Journal:  BMJ       Date:  2001-03-03

3.  Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults.

Authors:  Eoin O'Brien; Thomas Pickering; Roland Asmar; Martin Myers; Gianfranco Parati; Jan Staessen; Thomas Mengden; Yutaka Imai; Bernard Waeber; Paolo Palatini; William Gerin
Journal:  Blood Press Monit       Date:  2002-02       Impact factor: 1.444

4.  Evaluation of instruments for noninvasive blood pressure monitoring of the wrist.

Authors:  N S Latman; A Latman
Journal:  Biomed Instrum Technol       Date:  1997 Jan-Feb

5.  Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

Authors:  Wei-Fang Zeng; Qi-Fang Huang; Chang-Sheng Sheng; Yan Li; Ji-Guang Wang
Journal:  Blood Press Monit       Date:  2012-02       Impact factor: 1.444

6.  Reliability of palpation of the radial artery compared with auscultation of the brachial artery in measuring SBP.

Authors:  Niels V van der Hoeven; Bert-Jan H van den Born; Gert A van Montfrans
Journal:  J Hypertens       Date:  2011-01       Impact factor: 4.844

7.  Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

Authors:  Thomas G Pickering; John E Hall; Lawrence J Appel; Bonita E Falkner; John Graves; Martha N Hill; Daniel W Jones; Theodore Kurtz; Sheldon G Sheps; Edward J Roccella
Journal:  Circulation       Date:  2005-02-08       Impact factor: 29.690

8.  Effect of hypertransfusion on the gastrointestinal tract after cardiac arrest in a porcine model.

Authors:  Yi Lu; Chun-Sheng Li; Shuo Wang
Journal:  World J Emerg Med       Date:  2012

Review 9.  Does it matter where we measure blood pressure?

Authors:  Laurie A Tomlinson; Ian B Wilkinson
Journal:  Br J Clin Pharmacol       Date:  2012-08       Impact factor: 4.335

10.  Study for the discrepancy of arterial blood pressure in accordance with method, age, body part of measurement during general anesthesia using sevoflurane.

Authors:  Ji Ho Lee; Joung-Min Kim; Ki Ryang Ahn; Chun Sook Kim; Kyu Sik Kang; Jin Hun Chung; Ji-Won Chung; Sie Hyeon Yoo
Journal:  Korean J Anesthesiol       Date:  2011-05-31
View more
  4 in total

1.  Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.

Authors:  Willem J Verberk; Hao-Min Cheng; Li-Chih Huang; Chia-Ming Lin; Yao-Pin Teng; Chen-Huan Chen
Journal:  Pulse (Basel)       Date:  2016-02-12

2.  Significance of blood pressure variability in patients with sepsis.

Authors:  Nishant Raj Pandey; Yu-Yao Bian; Song-Tao Shou
Journal:  World J Emerg Med       Date:  2014

3.  Consumption of Cuban Policosanol Improves Blood Pressure and Lipid Profile via Enhancement of HDL Functionality in Healthy Women Subjects: Randomized, Double-Blinded, and Placebo-Controlled Study.

Authors:  Kyung-Hyun Cho; Suk-Jeong Kim; Dhananjay Yadav; Jae-Yong Kim; Jae-Ryong Kim
Journal:  Oxid Med Cell Longev       Date:  2018-04-16       Impact factor: 6.543

4.  Long-Term Consumption of Cuban Policosanol Lowers Central and Brachial Blood Pressure and Improves Lipid Profile With Enhancement of Lipoprotein Properties in Healthy Korean Participants.

Authors:  Suk-Jeong Kim; Dhananjay Yadav; Hye-Jeong Park; Jae-Ryong Kim; Kyung-Hyun Cho
Journal:  Front Physiol       Date:  2018-04-24       Impact factor: 4.566

  4 in total