Literature DB >> 9049918

Effect of continuous pressure on histopathological changes in denture-supporting tissues.

S Mori1, T Sato, T Hara, K Nakashima, S Minagi.   

Abstract

The histopathological changes in denture-supporting tissues were studied in relation to continuous pressure exerted through an experimental denture base. The experimental dentures were designed to load continuous pressures (1.5, 3.4 or 4.9 kPa) to the palate of molar region of rat. Histopathological changes caused by the continuous pressure were observed, and the intensity of the pressure was also estimated. A high correlation was observed between the histopathological changes under the denture base and the intensity of the continuous pressure. In groups exposed to 4.9 and 3.4 kPa, the continuous mechanical pressure caused bone resorption; in 1.5 kPa group, no evidence of bone resorption was observed. The epithelium and lamina propria mucosa under the denture base, which were compressed by the continuous pressure, recovered histopathologically depending on the decrease of the pressure caused by bone resorption; no quantitative recovery of the absorbed bone tissue was observed. No inflammatory change was induced by the continuous pressure. From the histopathological results observed in this study, the possibility of the existence of a threshold for bone resorption induced by continuous pressure was suggested.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9049918     DOI: 10.1046/j.1365-2842.1997.00443.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  8 in total

1.  Molar inclination and surrounding alveolar bone change relative to the design of bone-borne maxillary expanders: A CBCT study.

Authors:  Hyung-Wook Moon; Min-Jung Kim; Hyo-Won Ahn; Su-Jung Kim; Seong-Hun Kim; Kyu-Rhim Chung; Gerald Nelson
Journal:  Angle Orthod       Date:  2019-08-28       Impact factor: 2.079

2.  A Surgical Technique for the Management of Suction Cup-Induced Palatal Perforation: A Technical Note.

Authors:  Amin Rahpeyma; Saeedeh Khajehahmadi
Journal:  J Clin Diagn Res       Date:  2015-07-01

3.  Fabrication of a multi-applicable removable intraoral denture system for rodent research.

Authors:  H Lee; A Yu; C C Johnson; E A Lilly; M C Noverr; P L Fidel
Journal:  J Oral Rehabil       Date:  2011-02-17       Impact factor: 3.837

4.  Shape Optimization for Additive Manufacturing of Removable Partial Dentures--A New Paradigm for Prosthetic CAD/CAM.

Authors:  Junning Chen; Rohana Ahmad; Hanako Suenaga; Wei Li; Keiichi Sasaki; Michael Swain; Qing Li
Journal:  PLoS One       Date:  2015-07-10       Impact factor: 3.240

5.  Effect of Denture Tooth Material on Load Transmission Under Denture Bases.

Authors:  Ramin Mosharraf; Farzad Ziaei; Mahsa Abbasi
Journal:  J Dent (Tehran)       Date:  2018-09

6.  A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK.

Authors:  Xin Chen; Bochun Mao; Zhuoli Zhu; Jiayi Yu; Yuqing Lu; Qianqian Zhang; Li Yue; Haiyang Yu
Journal:  Sci Rep       Date:  2019-09-27       Impact factor: 4.379

7.  Concurrent management of nasal bone expansion from nasal polyposis (Woakes' disease).

Authors:  Alexander Dickie; Brian Rotenberg; Leigh Sowerby
Journal:  Laryngoscope Investig Otolaryngol       Date:  2022-08-09

Review 8.  Biomechanics of oral mucosa.

Authors:  Junning Chen; Rohana Ahmad; Wei Li; Michael Swain; Qing Li
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.