Ramin Mosharraf1, Farzad Ziaei2, Mahsa Abbasi3.
Abstract
OBJECTIVES: Pressure transmission under denture bases can vary depending on the denture tooth material. The aim of the present study was to evaluate pressure transmission under denture bases using denture teeth of different materials in direct and indirect tooth contacts.Entities:
Keywords: Acrylic Resins; Artificial Tooth; Denture Bases; Occlusal Forces; Pressure
Year: 2018 PMID: 30833979 PMCID: PMC6397739
Source DB: PubMed Journal: J Dent (Tehran) ISSN: 1735-2150
Materials used in the study
| Super-Newclar (acrylic resin with 7% cross-linking) | Ideal Makoo Co. | Tehran, Iran | N3 | A3 | |
| Super-Brilian (composite-acrylic resin) | Ideal Makoo Co. | Tehran, Iran | N3 | A3 | |
| B-star (nanocomposite) | Ideal Makoo Co. | Tehran, Iran | N3 | A3 | |
| Global Hawk nano steel teeth (ceramic teeth) | Caiyu Dental Materials Factory | Huizhou, China | 30 | A3 | |
| Acrylic resin denture base materia | Meliodent, Bayer Dental | Newbury, UK | - | - |
AR=Acrylic Resin, C-AR=Composite-Acrylic Resin, NC=Nanocomposite, CR=Ceramic, DBR=Denture Base Resin
Fig. 1:A dental surveyor was used to place each denture tooth on the surface of the wax perpendicular to the occlusal surface
Fig. 2:A specimen in the chewing simulator machine
Means and standard deviations (SD) of maximum pressure (MPa) transmission in direct 2-body and indirect 3-body contacts, and the results of the comparisons made using post-hoc Tukey's test
| 10 | 5.2280(±0.15017) a | 1.6310(±0.12723) A | |
| 10 | 4.6320(±0.06443) b | 2.0420(±0.10075) B | |
| 10 | 4.4940(±0.09845) b,c | 2.2120(±0.10902) C | |
| 10 | 4.253(±0.1542) d | 1.948(±0.07421) B,D | |
| 10 | 3.808(±0.12444) e | 2.446(±0.0782) E |
AR=Acrylic Resin, C-AR=Composite-Acrylic Resin, NC=Nanocomposite, CR=Ceramic, DBR=Denture Base Resin;
Different letters show a significant difference between the groups (P<0.05)
One-way analysis of variance (ANOVA) for direct and indirect pressure transmission with different materials
|
|
|
|
|
| ||
|---|---|---|---|---|---|---|
|
| Intergroup | 10.859 | 4 | 2.715 | 179.403 | P< 0.001 |
| Intragroup | .681 | 45 | .015 | |||
| Total | 11.540 | 49 | ||||
|
| Intergroup | 3.689 | 4 | .922 | 92.516 | P< 0.001 |
| Intragroup | .449 | 45 | .010 | |||
| Total | 4.138 | 49 |
df=degree of freedom
Fig. 3:Spot diagram showing linear correlation between direct 2-body and indirect 3-body tooth contacts. Direct and indirect pressures are in MPa