Quantitative evaluation of radiochromic film response for two-dimensional dosimetry.

Y Zhu1, A S Kirov, V Mishra, A S Meigooni, J F Williamson.   

Abstract

Radiochromic film (RCF) is attractive as a thin, high resolution, 2D planar dosimeter. We have studied the uniformity, linearity, and reproducibility of a commercially supplied RCF system (model MD-55). Forty 12 cm long strips of RCF were exposed to uniform doses of 6 MV x rays. Optical density (OD) distributions were measured by a helium-neon scanning laser (633 nm) 2D densitometer and also with a manual densitometer. All film strips showed 8%-15% variations in OD values independent of densitometry technique which are evidently due to nonuniform dispersal of the sensor medium. A double exposure technique was developed to solve this problem. The film is first exposed to a uniform beam, which defines a pixel-by-pixel nonuniformity correction matrix. The film is then exposed to the unknown dose distribution, rescanned, and the net OD at each pixel corrected for nonuniformity. The double exposure technique reduces OD/unit dose variation to a 2%-5% random fluctuation. RCF response was found to deviate significantly from linearity at low doses (40% change in net OD/Gy from 1 to 30 Gy); a finding not previously reported. To study the tradeoff between statistical noise and spatial resolution, OD was averaged over blocks of adjacent 50 microns pixels (ranging from 1 x 1 to 10 x 10 pixels). Reproducibility, defined as the standard deviation of repeated single-pixel measurements on separate film pieces, was 2% at 30 Gy for a resolution of 0.25 mm. With careful correction for nonlinearity and nonuniformity, RCF is a promising quantitative 2D dosimeter for radiation oncology applications.

Entities:  

Mesh:

Year:  1997        PMID: 9048362     DOI: 10.1118/1.598068

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

Review 1.  A preliminary comparison of total skin electron treatment techniques to demonstrate the application of a mid-torso phantom for measurement of dose penetration.

Authors:  G Baugh; T Al-Alawi; C L Fletcher; J A Mills; R J Grieve
Journal:  Br J Radiol       Date:  2011-02-08       Impact factor: 3.039

2.  Evaluation of gafchromic EBT film for intensity modulated radiation therapy dose distribution verification.

Authors:  A Sankar; P G Goplakrishna Kurup; V Murali; Komanduri M Ayyangar; R Mothilal Nehru; J Velmurugan
Journal:  J Med Phys       Date:  2006-04

3.  An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.

Authors:  David Lewis; Andre Micke; Xiang Yu; Maria F Chan
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

4.  Ultraviolet exposure of Gafchromic XR-RV3 and XR-SP2 films.

Authors:  Toshizo Katsuda; Rumi Gotanda; Tatsuhiro Gotanda; Takuya Akagawa; Nobuyoshi Tanki; Tadao Kuwano; Kouichi Yabunaka
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

5.  Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films.

Authors:  Sharifeh A Dini; Rafiq A Koona; John R Ashburn; Ali S Meigoonia
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

6.  Intensities of Incident and Transmitted Ultraviolet-A Rays through Gafchromic Films.

Authors:  Toshizo Katsuda; Rumi Gotanda; Tatsuhiro Gotanda; Takuya Akagawa; Nobuyoshi Tanki; Tadao Kuwano; Atsushi Noguchi; Kouichi Yabunaka
Journal:  J Med Phys       Date:  2017 Apr-Jun

7.  Comparing three UV wavelengths for pre-exposing Gafchromic EBT2 and EBT3 films.

Authors:  Toshizo Katsuda; Rumi Gotanda; Tatsuhiro Gotanda; Takuya Akagawa; Nobuyoshi Tanki; Tadao Kuwano; Kouichi Yabunaka
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

8.  Suitability of radiochromic films for dosimetry of very-low energy X-rays.

Authors:  Martin A Ebert; Ali H Asad; Salim A Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2009-09-02       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.