Literature DB >> 21304004

A preliminary comparison of total skin electron treatment techniques to demonstrate the application of a mid-torso phantom for measurement of dose penetration.

G Baugh1, T Al-Alawi, C L Fletcher, J A Mills, R J Grieve.   

Abstract

OBJECTIVES: In the UK, the treatment of patients with mycosis fungoides using total skin electron (TSE) beam therapy is undertaken using a number of different irradiation techniques. As part of a review of these techniques, a comparative set of measurements would be useful to determine how the techniques differ in terms of dose distribution. A dose penetration intercomparison method that could be used as part of such a study is presented here.
METHODS: The dose penetrations for six treatment techniques currently or recently used in four centres in the UK were measured. The variation of dose with skin depth was measured in a WT1 solid water mid-torso phantom. The phantom is portable and suitable to be used in all the techniques. It is designed to hold four small radiochromic film dosemeters to investigate the variation in dose around the mid-torso. For each treatment technique, the phantom was irradiated using the clinical set-up.
RESULTS: The phantom performed well and was able to measure dose penetration and the uniformity of penetration for several treatment techniques.
CONCLUSION: These preliminary results demonstrate that there is some variation in dose distribution between different TSE treatment techniques and that the phantom could be used in a more comprehensive intercomparison. The results are not intended to demonstrate comprehensively the range of penetration that can be achieved in clinical practice as, for one of the treatment techniques, the penetration is customised for the extent of the disease.

Entities:  

Mesh:

Year:  2011        PMID: 21304004      PMCID: PMC3473835          DOI: 10.1259/bjr/52924135

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

1.  Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film.

Authors:  Lisa M Gamble; Thomas J Farrell; Glenn W Jones; Joseph E Hayward
Journal:  Phys Med Biol       Date:  2003-04-07       Impact factor: 3.609

2.  Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine.

Authors:  A Niroomand-Rad; C R Blackwell; B M Coursey; K P Gall; J M Galvin; W L McLaughlin; A S Meigooni; R Nath; J E Rodgers; C G Soares
Journal:  Med Phys       Date:  1998-11       Impact factor: 4.071

3.  GafChromic MD-55: investigated as a precision dosimeter.

Authors:  N V Klassen; L van der Zwan; J Cygler
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

4.  Quantitative evaluation of radiochromic film response for two-dimensional dosimetry.

Authors:  Y Zhu; A S Kirov; V Mishra; A S Meigooni; J F Williamson
Journal:  Med Phys       Date:  1997-02       Impact factor: 4.071

5.  Practical approach to electron beam dosimetry at extended SSD.

Authors:  J Cygler; X A Li; G X Ding; E Lawrence
Journal:  Phys Med Biol       Date:  1997-08       Impact factor: 3.609

Review 6.  Electron beam treatment for cutaneous T-cell lymphoma.

Authors:  G W Jones; R T Hoppe; E Glatstein
Journal:  Hematol Oncol Clin North Am       Date:  1995-10       Impact factor: 3.722

7.  Clinical aspects of a rotational total skin electron irradiation.

Authors:  T H Kim; C Pla; M Pla; E B Podgorsak
Journal:  Br J Radiol       Date:  1984-06       Impact factor: 3.039

8.  Total skin electron radiation in the management of mycosis fungoides: Consensus of the European Organization for Research and Treatment of Cancer (EORTC) Cutaneous Lymphoma Project Group.

Authors:  Glenn W Jones; Barry M Kacinski; Lynn D Wilson; Rein Willemze; Margaret Spittle; Gerda Hohenberg; Leonore Handl-Zeller; Franz Trautinger; Robert Knobler
Journal:  J Am Acad Dermatol       Date:  2002-09       Impact factor: 11.527

  8 in total
  2 in total

Review 1.  Review of the results of the in vivo dosimetry during total skin electron beam therapy.

Authors:  Gabriele Guidi; Giovanni Gottardi; Paola Ceroni; Tiziana Costi
Journal:  Rep Pract Oncol Radiother       Date:  2013-08-15

2.  Evaluation of Dose Distribution in Optimized Stanford Total Skin Electron Therapy (TSET) Technique in Rando Anthropomorphic Phantom using EBT3 Gafchromatic Films.

Authors:  Shaghayegh Fahimi Monzari; Ghazale Geraily; Mehdi Aghili; Heydar Toolee
Journal:  J Biomed Phys Eng       Date:  2021-08-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.