Hemodynamic performance of small aortic valve bioprostheses: is there a difference?

M L McDonald1, R C Daly, H V Schaff, C J Mullany, F A Miller, J J Morris, T A Orszulak.   

Abstract

BACKGROUND: There is the potential for left ventricular outflow obstruction when small aortic valve bioprostheses are employed in normal-sized or large adults. It has been hoped that bovine pericardial valves would improve hemodynamic performance in the smaller tissue valve sizes.
METHODS: To determine in vivo hemodynamic performance of heterograft aortic valve prostheses, we analyzed echocardiographic data from patients receiving 21- or 23-mm Carpentier-Edwards pericardial, Medtronic Intact, and Carpentier-Edwards porcine bioprostheses. In addition, data from 19-mm Carpentier-Edwards pericardial valves were included for comparison of hemodynamic performance between valve sizes. Doppler echocardiography was performed in 151 patients within 2 weeks of operation. Left ventricular outflow gradient was derived from continuous Doppler measurements of flow velocity, and effective orifice area was calculated by the continuity equation.
RESULTS: There were statistically significant differences in hemodynamic performance of different sized prostheses for each valve type (effective orifice area, p < 0.01; valvular gradient, p < 0.03). There were, however, no significant differences in effective orifice area or mean gradient for different valve types within each size category.
CONCLUSIONS: The in vivo hemodynamic performance of these three different aortic valve heterograft bioprostheses is similar. Patient-prosthesis mismatch with heterograft prostheses, as demonstrated by the indexed effective orifice area can be avoided by appropriate sizing and use of annular enlarging techniques when necessary.

Entities:  

Mesh:

Year:  1997        PMID: 9033301     DOI: 10.1016/s0003-4975(96)01225-8

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

Review 1.  Lack of Accessible Data on Prosthetic Heart Valves.

Authors:  Michelle Frank; Giulia Ganzoni; Christoph Starck; Jürg Grünenfelder; Roberto Corti; Christiane Gruner; David Hürlimann; Felix C Tanner; Rolf Jenni; Matthias Greutmann; Patric Biaggi
Journal:  Int J Cardiovasc Imaging       Date:  2015-12-08       Impact factor: 2.357

Review 2.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

3.  Patient-prosthesis mismatch may be irrelevant after aortic valve replacement with the 19-mm Perimount pericardial bioprosthesis in patients aged 65 years or older.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto; Hiroshi Okuyama; Tatsuumi Sasaki; Hiromitsu Takakura; Katsuhisa Onoguchi
Journal:  J Artif Organs       Date:  2007-12-20       Impact factor: 1.731