Fixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups.

V G Williams1, L A Whiteside, S E White, D S McCarthy.   

Abstract

Locking mechanisms and metal-liner interface surfaces of six modular acetabular systems were evaluated to determine their effect on micromotion and backside wear of the polyethylene liner. Rotational and axial motion between the metal shell and polyethylene liner was measured in the Duraloc (DePuy, Warsaw, IN), Harris-Galante (Zimmer, Warsaw, IN), Impact (Biomet, Warsaw, IN), Lip Loc (Biomet), Precision Osteoloc (Howmedica, Rutherford, NJ), and Reflection (Smith & Nephew Orthopaedics, Memphis, TN) designs at the start of each test, and at 1 million, 5 million, and 10 million cycles. At 10 million cycles, the Lip Loc and Reflection cups had significantly lower rim micromotion than the Duraloc and Harris-Galante cups (F < .0010). The Impact, Precision Osteoloc, and Reflection cups had significantly lower rim subsidence than the Harris-Galante cup (F < .0025). The Harris-Galante cup had significantly greater rotational micromotion than the Lip Loc cup (F < .0074), and had significantly greater interface slippage than the Impact and Reflection cups (F < .0070). The Lip Loc produced significantly lower dome micromotion than the Harris-Galante (F < .0300). The Lip Loc and Reflection cups had significantly less backside wear than the Duraloc and Harris-Galante cups (P < .0001), the Impact cup (P < .0243), and the Precision Osteoloc (P < .0027) cup.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9021498     DOI: 10.1016/s0883-5403(97)90043-7

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Increased volumetric wear of polyethylene liners with more than 3 years of shelf-life time.

Authors:  T J S Puolakka; J T Keränen; K A Juhola; K J J Pajamäki; P J Halonen; J K Nevalainen; V Saikko; M U K Lehto; M Järvinen
Journal:  Int Orthop       Date:  2003-04-01       Impact factor: 3.075

2.  Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis.

Authors:  Adolph V Lombardi; Keith R Berend; Brian E Seng; Ian C Clarke; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

3.  Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners.

Authors:  Kamal Bali; Richard W McCalden; Douglas D R Naudie; Steven J MacDonald; Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

4.  Cementless Revision Total Hip Arthroplasty with Ceramic Articulation.

Authors:  Jong-Hyuck Yang; Seong-Jo Yang; Joon-Soon Kang; Kyoung-Ho Moon
Journal:  Hip Pelvis       Date:  2015-12-30

5.  Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro.

Authors:  Ana Laura Puente Reyna; Marcus Jäger; Thilo Floerkemeier; Sven Frecher; Karl-Stefan Delank; Christoph Schilling; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2016-09-19       Impact factor: 3.411

6.  Pigmented villonodular synovitis does not influence the outcome following cementless total hip arthroplasty using ceramic-on-ceramic articulation: a case-control study with middle-term follow-up.

Authors:  Chi Xu; Heng Guo; Kerri L Bell; Feng-Chih Kuo; Ji-Ying Chen
Journal:  J Orthop Surg Res       Date:  2018-11-20       Impact factor: 2.359

7.  Comparison of Different Locking Mechanisms in Total Hip Arthroplasty: Relative Motion between Cup and Inlay.

Authors:  Sebastian Jaeger; Maximilian Uhler; Stefan Schroeder; Nicholas A Beckmann; Steffen Braun
Journal:  Materials (Basel)       Date:  2020-03-19       Impact factor: 3.623