Variability of a three-layered appearance in intravascular ultrasound coronary images: a comparison of morphometric measurements with four intravascular ultrasound systems.

T Hiro1, C Y Leung, R J Russo, H Karimi, A R Farvid, J M Tobis.   

Abstract

The purpose of the study was to compare four intravascular ultrasound (IVUS) machines in vitro for their image representation of coronary arterial walls. There has been considerable variability among reported studies on the accuracy of morphometric measurements of coronary arteries by IVUS. This variability may be caused in part by the difference in the IVUS system used. A total of 24 formalin-fixed coronary arteries were imaged in saline at 37 degrees with four different IVUS systems. The images were interpreted independently and compared with histology. Each system had benefits and limitations: System 1 overestimated the lumen area and had difficulty in identifying the media; System 2 underestimated the media area, but had a lower positive bias for lumen area; System 3 overestimated the lumen area but more clearly identified tissue characteristics such as internal elastic membrane and the echolucent media zone which improved the likelihood of observing a three-layer appearance; and System 4 showed less distinct separation of the arterial components and had poor correlations with histology for media measurements. The ability to make accurate morphometric measurements from IVUS images depends on the clarity of the separation of plaque and media. Among the four systems studied, there is significant variability in the appearance of the ultrasound images and the accuracy of morphometric measurements. These system differences should be considered when comparing IVUS studies performed by different groups.

Entities:  

Mesh:

Year:  1996        PMID: 9012388

Source DB:  PubMed          Journal:  Am J Card Imaging        ISSN: 0887-7971


  6 in total

1.  Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

Authors:  J C Tardif; O F Bertrand; R Mongrain; J Lespérance; J Grégoire; P Paiement; R Bonan
Journal:  Int J Card Imaging       Date:  2000-10

2.  In vivo variability in quantitative coronary ultrasound and tissue characterization measurements with mechanical and phased-array catheters.

Authors:  Gastón A Rodriguez-Granillo; Eugène P McFadden; Jiro Aoki; Carlos A G van Mieghem; Evelyn Regar; Nico Bruining; Patrick W Serruys
Journal:  Int J Cardiovasc Imaging       Date:  2005-12-14       Impact factor: 2.357

3.  Dedicated calibration formulas permit correction of differences between measurements by different IVUS devices as demonstrated in atherosclerotic human coronary arteries in vitro.

Authors:  Marc Hartmann; Clemens von Birgelen; Gary S Mintz; Nadine Deppermann; Olaf Dirsch; Martin G Stoel; Gert K van Houwelingen; Hans W Louwerenburg; Patrick M J Verhorst; Raimund Erbel
Journal:  Int J Cardiovasc Imaging       Date:  2006-04-29       Impact factor: 2.357

Review 4.  [Methods for coronary functional assessment].

Authors:  M Elsner
Journal:  Herz       Date:  1998-03       Impact factor: 1.443

Review 5.  Intravascular ultrasound: principles and cerebrovascular applications.

Authors:  H Zacharatos; A E Hassan; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-04       Impact factor: 3.825

6.  Quantitative precision of optical frequency domain imaging: direct comparison with frequency domain optical coherence tomography and intravascular ultrasound.

Authors:  Yuhei Kobayashi; Hideki Kitahara; Shigemitsu Tanaka; Kozo Okada; Takumi Kimura; Fumiaki Ikeno; Paul G Yock; Peter J Fitzgerald; Yasuhiro Honda
Journal:  Cardiovasc Interv Ther       Date:  2015-08-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.