Literature DB >> 9002830

Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits.

C J Ivanoff1, L Sennerby, U Lekholm.   

Abstract

In the present study, the influence of initial instability on the healing of titanium implants was studied in 9 lop-eared rabbits. Titanium implants (Brånemark System) were inserted in the tibiae, a location with cortical bone only, in such a way that they were either stable (control), rotation-mobile, or totally mobile. Implants were also inserted in the distal femoral condyles, representing an implantation bed with mainly cancellous bone, so they either showed no initial mobility (control) or were rotation-mobile. After 12 weeks of healing, the implants were retrieved, together with surrounding bone, fixed, dehydrated, and embedded in plastic resin. About 10 micron thick ground sections were prepared for light microscopic morphometry. The mineralized bone to titanium contact, and the amount of bone occupying the threads, were calculated, whereafter the outcome of the different locations were compared. All retrieved implants were clinically stable at the of the experiment. For the tibia sites, a statistically significant less bone to titanium contact, and a less amount of bone in the threads, were found for the totally mobile implants, as compared to the corresponding initially stable controls. Moreover, a statistically significant higher amount of bone was found in the threads of the rotation-mobile implants inserted in the femoral condyle as compared to their initially stable controls. The study indicated that initial rotation-mobility, independent if it occurs in cortical or trabecular bone, does not necessarily lead to an inferior integration of unloaded implants. However, initial total implant mobility within the cortical layer results in a statistically significant less amount of bone around the implants, as compared to stable controls.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9002830

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  12 in total

Review 1.  Implant surface characteristics and their effect on osseointegration.

Authors:  A Barfeie; J Wilson; J Rees
Journal:  Br Dent J       Date:  2015-03-13       Impact factor: 1.626

2.  Peri-implant bone reactions around immediately loaded conical implants with different prosthetic suprastructures: histological and histomorphometrical study on minipigs.

Authors:  Bartolomeo Assenza; Antonio Scarano; Vittoria Perrotti; Iole Vozza; Alessandro Quaranta; Manlio Quaranta; Adriano Piattelli; Giovanna Iezzi
Journal:  Clin Oral Investig       Date:  2009-06-04       Impact factor: 3.573

3.  Development of implant loading device for animal study about various loading protocol: a pilot study.

Authors:  Joon-Ho Yoon; Young-Bum Park; Yuna Cho; Chang-Sung Kim; Seong-Ho Choi; Hong-Seok Moon; Keun-Woo Lee; June-Sung Shim
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

4.  Biological and biomechanical evaluation of interface reaction at conical screw-type implants.

Authors:  Andre Büchter; Ulrich Joos; Hans-Peter Wiesmann; László Seper; Ulrich Meyer
Journal:  Head Face Med       Date:  2006-02-21       Impact factor: 2.151

5.  Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study.

Authors:  Mariano Herrero-Climent; Rocio Santos-García; Reyes Jaramillo-Santos; Manuel-Maria Romero-Ruiz; Ana Fernández-Palacin; Pedro Lázaro-Calvo; Pedro Bullón; Jose-Vicente Ríos-Santos
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-11-01

6.  2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

Authors:  Shrikar R Desai; Rika Singh; I Karthikeyan
Journal:  J Indian Soc Periodontol       Date:  2013-09

7.  Bone cement grafting increases implant primary stability in circumferential cortical bone defects.

Authors:  Seung-Yun Shin; Seung-Il Shin; Seung-Beom Kye; Seok-Woo Chang; Jongrak Hong; Jun-Young Paeng; Seung-Min Yang
Journal:  J Periodontal Implant Sci       Date:  2015-02-25       Impact factor: 2.614

8.  Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis.

Authors:  Kenko Tanaka; Irena Sailer; Ryosuke Iwama; Kensuke Yamauchi; Shinnosuke Nogami; Nobuhiro Yoda; Tetsu Takahashi
Journal:  J Periodontal Implant Sci       Date:  2018-12-27       Impact factor: 2.614

9.  Bone implant sockets made using three different procedures: a stability study in dogs.

Authors:  Jorge Cano; Julián Campo
Journal:  J Clin Exp Dent       Date:  2012-10-01

10.  Primary stability of self-drilling and self-tapping mini-implant in tibia of diabetes-induced rabbits.

Authors:  Jea-Beom Park; Eun-Young Kim; Janghyun Paek; Yoon-Ah Kook; Do-Min Jeong; Il-Sik Cho; Gerald Nelson
Journal:  Int J Dent       Date:  2014-05-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.