Literature DB >> 8986569

Clinical and radiographic results of the Total Condylar III and Constrained Condylar total knee arthroplasty.

P F Lachiewicz1, S P Falatyn.   

Abstract

The Total Condylar III (Johnson and Johnson, Braintree, MA) and Constrained Condylar (Zimmer, Warsaw, IN) knee prostheses are nonlinked, semi-constrained prosthetic alternatives to rigid or rotating hinge prostheses for use in complex knee reconstructions. Forty-six Total Condylar III or Constrained Condylar prostheses were implanted with cement in 36 patients and followed for a mean of 5 years (range, 2-9 years). There were 25 primary total knee arthroplasties and 21 revision total knee arthroplasties. The knees were evaluated using The Hospital for Special Surgery 100-point knee rating system. Overall, 40 knees (87%) had a good or excellent clinical result, 2 knees (4%) had a fair result, and 4 knees (9%) had a poor result. There was one revision for loosening of a cemented, nonmodular Constrained Condylar prosthesis, and one knee had a debridement for a late, metastatic infection, but the components were retained. There were no mechanical failures in those knees that were primary arthroplasties, but two mechanical failures occurred in those knees that were revision arthroplasties. Radiographic review showed one asymptomatic loosening of a Constrained Condylar tibial component with an uncemented press-fit stem, and only 8 knees had scattered nonprogressive tibial bone-cement radiolucent lines. The Total Condylar III and Constrained Condylar semiconstrained prostheses are successful when used in complex knee reconstructions.

Entities:  

Mesh:

Year:  1996        PMID: 8986569     DOI: 10.1016/s0883-5403(96)80132-x

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  12 in total

1.  Minimizing dynamic knee spacer complications in infected revision arthroplasty.

Authors:  Aaron J Johnson; Siraj A Sayeed; Qais Naziri; Harpal S Khanuja; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

2.  [Diagnosis specific differences in knee joint geometry. A challenge for the correct axial implantation of long stems in total knee arthroplasty].

Authors:  M Goebel; R Burgkart; L Gerdesmeyer; P Diehl; M Schmitt-Sody; W Plötz; R Gradinger
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

3.  Primary modular total knee replacement in severe and unstable osteoarthritis. Predictive factors for failure.

Authors:  Rafael Luque; Belen Rizo; Antonio Urda; Rodrigo Garcia-Crespo; Enrique Moro; Luis López-Durán
Journal:  Int Orthop       Date:  2015-07-01       Impact factor: 3.075

4.  Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees.

Authors:  Jae-Hyuk Yang; Jung-Ro Yoon; Chi-Hun Oh; Taik-Sun Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-20       Impact factor: 4.342

5.  Clinical results and failure mechanisms of a nonmodular constrained knee without stem extensions.

Authors:  Denis Nam; Ben-Paul N Umunna; Michael B Cross; Keith R Reinhardt; Shivi Duggal; Charles N Cornell
Journal:  HSS J       Date:  2012-05-12

6.  SCREW MIGRATION IN TOTAL KNEE ARTHROPLASTY: CLINICAL REPORT.

Authors:  Fernando Fonseca; José Tomé; Manuel Barreto
Journal:  Rev Bras Ortop       Date:  2015-11-16

Review 7.  Is varus-valgus constraint a reliable option in complex primary total knee arthroplasty? A systematic review.

Authors:  Fabio Mancino; Francesco Falez; Fabrizio Mocini; Peter K Sculco; Giulio Maccauro; Ivan De Martino
Journal:  J Orthop       Date:  2021-03-06

8.  Conversion of fused knee following distal femur tumor surgery to total knee arthroplasty.

Authors:  Khodamorad Jamshidi; Hoseinali Hadi; Mehdi Ramezan Shirazi; Alireza Moslem
Journal:  Iran Red Crescent Med J       Date:  2013-09-05       Impact factor: 0.611

9.  Results of a Second-generation Constrained Condylar Prosthesis in Complex Primary and Revision Total Knee Arthroplasty: A Mean 5.5-Year Follow-up.

Authors:  Chen-Yi Ye; De-Ting Xue; Shuai Jiang; Rong-Xin He
Journal:  Chin Med J (Engl)       Date:  2016-06-05       Impact factor: 2.628

10.  Early results of a new rotating hinge knee implant.

Authors:  Alexander Giurea; Hans-Joachim Neuhaus; Rolf Miehlke; Reinhard Schuh; Richard Lass; Bernd Kubista; Reinhard Windhager
Journal:  Biomed Res Int       Date:  2014-06-25       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.