Literature DB >> 8976990

Consequences of monocular diplopia for the contrast sensitivity function.

R L Woods1, A Bradley, D A Atchison.   

Abstract

Though the human eye generally creates a single image on the retina, the literature contains many examples showing perceptual monocular diplopia. Previously, monocular diplopia resulting from astigmatic defocus has been demonstrated to cause a notch (local minimum) in the contrast sensitivity function (CSF). We examine Verhoeff's (1900) model which explains how monocular diplopia can occur through an interaction between defocus and common ocular aberrations. From the measured ocular transverse aberration function and from the measured monocular diplopia of three cyclopleged subjects we predicted multiple notches in the CSF with hyperopic spherical defocus. Monochromatic and polychromatic CSF were measured for vertical gratings with best refraction and with simulated myopia and hyperopia. Multiple notches in CSF were observed experimentally. Notches in the polychromatic CSF were smaller and broader than those found in the monochromatic CSF. Our aberration model was successful in predicting notches in the CSF with hyperopic spherical defocus. The implications for clinical measurement of CSF are discussed.

Entities:  

Mesh:

Year:  1996        PMID: 8976990     DOI: 10.1016/0042-6989(96)00091-0

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  5 in total

1.  Bayesian adaptive estimation of the contrast sensitivity function: the quick CSF method.

Authors:  Luis Andres Lesmes; Zhong-Lin Lu; Jongsoo Baek; Thomas D Albright
Journal:  J Vis       Date:  2010-03-30       Impact factor: 2.240

2.  Visual impact of Zernike and Seidel forms of monochromatic aberrations.

Authors:  Xu Cheng; Arthur Bradley; Sowmya Ravikumar; Larry N Thibos
Journal:  Optom Vis Sci       Date:  2010-05       Impact factor: 1.973

3.  Improving vision: neural compensation for optical defocus.

Authors:  M Mon-Williams; J R Tresilian; N C Strang; P Kochhar; J P Wann
Journal:  Proc Biol Sci       Date:  1998-01-07       Impact factor: 5.349

4.  Monocular diplopia due to spherocylindrical refractive errors (an American Ophthalmological Society thesis).

Authors:  Steven M Archer
Journal:  Trans Am Ophthalmol Soc       Date:  2007

5.  Bayesian Inference of Two-Dimensional Contrast Sensitivity Function from Data Obtained with Classical One-Dimensional Algorithms Is Efficient.

Authors:  Xiaoxiao Wang; Huan Wang; Jinfeng Huang; Yifeng Zhou; Tzvetomir Tzvetanov
Journal:  Front Neurosci       Date:  2017-01-10       Impact factor: 4.677

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.