Literature DB >> 8976727

Extent and effect of surface tilt on the data display of the EyeSys videokeratoscope.

W A Douthwaite1, S Pardhan, H Burek.   

Abstract

AIMS: This study examined the occurrence, magnitude, and the consequences of a possible tilt between the corneal surface and optical axis of the EyeSys videokeratoscope.
METHODS: Initially, a theoretical model was developed to calculate the angle of tilt. The predictions of the model were verified empirically using a convex conicoid surface and were found to predict the tilt to within 0.5 degree of the actual tilt. The likely effects of the tilt on the corneal power were also examined. The angle of tilt was then measured on the human cornea and the effect of neutralising the tilt on the videokeratoscopic data display was observed.
RESULTS: The angle of tilt was found to lie between 1 degree and 6 degrees in a temporal direction.
CONCLUSION: When the corneal tilt on the human subjects was neutralised, then a reduction in the nasal/temporal asymmetry was observed.

Entities:  

Mesh:

Year:  1996        PMID: 8976727      PMCID: PMC505677          DOI: 10.1136/bjo.80.11.986

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  11 in total

Review 1.  Evaluation of corneal topography: past, present and future trends.

Authors:  G L Morrow; R M Stein
Journal:  Can J Ophthalmol       Date:  1992-08       Impact factor: 1.882

2.  Everett Kinsey Lecture. The enigma of the corneal contour.

Authors:  R B Mandell
Journal:  CLAO J       Date:  1992-10

3.  The measurement of the corneal ellipse for the contact lens practitioner.

Authors:  W A Douthwaite; M Sheridan
Journal:  Ophthalmic Physiol Opt       Date:  1989-07       Impact factor: 3.117

4.  Accuracy and precision of the corneal analysis system and the topographic modeling system.

Authors:  S E Wilson; S M Verity; D L Conger
Journal:  Cornea       Date:  1992-01       Impact factor: 2.651

5.  Computerized contact lens fitting.

Authors:  W A Douthwaite
Journal:  Optom Vis Sci       Date:  1991-10       Impact factor: 1.973

6.  Corneal topography: a clinical model.

Authors:  M Guillon; D P Lydon; C Wilson
Journal:  Ophthalmic Physiol Opt       Date:  1986       Impact factor: 3.117

7.  EyeSys corneal topography measurement applied to calibrated ellipsoidal convex surfaces.

Authors:  W A Douthwaite
Journal:  Br J Ophthalmol       Date:  1995-09       Impact factor: 4.638

8.  Mathematical models of the general corneal surface.

Authors:  H Burek; W A Douthwaite
Journal:  Ophthalmic Physiol Opt       Date:  1993-01       Impact factor: 3.117

9.  A comparison of the TMS-1 and the corneal analysis system for the evaluation of abnormal corneas.

Authors:  J J Antalis; R G Lembach; L G Carney
Journal:  CLAO J       Date:  1993-01

10.  Shape and refractive powers in corneal topography.

Authors:  S A Klein; R B Mandell
Journal:  Invest Ophthalmol Vis Sci       Date:  1995-09       Impact factor: 4.799

View more