Literature DB >> 8453755

A comparison of the TMS-1 and the corneal analysis system for the evaluation of abnormal corneas.

J J Antalis1, R G Lembach, L G Carney.   

Abstract

We used two computerized corneal topography instruments (EyeSys Laboratories' Corneal Analysis System and the Topographic Modeling System (TMS-1) from Computed Anatomy, Inc.] to evaluate 18 eyes (ten patients) with abnormal corneas. The diagnoses included keratoconus, corneal scars, and residual postoperative astigmatism following refractive surgery. The patients were randomly selected from a busy corneal practice to include those with significant corneal refractive error whose management, it was believed, would benefit from corneal topography imaging. Images were taken with both systems, and comparisons were made of the ease of operation, the accuracy of corneal readings, and the usefulness of generated data. Three millimeter zone (Corneal Analysis System) and Simulated Keratometry (TMS-1) values were also compared to each other and to standard keratometric readings. We found the two systems to be very similar in their application and results, although certain differences were apparent in terms of operation, patient acceptance, and the ability to obtain useful data from the more distorted corneas. Neither system worked ideally for severely irregular surfaces.

Entities:  

Mesh:

Year:  1993        PMID: 8453755     DOI: 10.1097/00140068-199301000-00011

Source DB:  PubMed          Journal:  CLAO J        ISSN: 0733-8902


  7 in total

1.  Corneal topography by keratometry.

Authors:  W A Douthwaite; W T Evardson
Journal:  Br J Ophthalmol       Date:  2000-08       Impact factor: 4.638

2.  Extent and effect of surface tilt on the data display of the EyeSys videokeratoscope.

Authors:  W A Douthwaite; S Pardhan; H Burek
Journal:  Br J Ophthalmol       Date:  1996-11       Impact factor: 4.638

3.  EyeSys corneal topography measurement applied to calibrated ellipsoidal convex surfaces.

Authors:  W A Douthwaite
Journal:  Br J Ophthalmol       Date:  1995-09       Impact factor: 4.638

4.  Information fidelity in corneal topography.

Authors:  S D Klyce
Journal:  Br J Ophthalmol       Date:  1995-09       Impact factor: 4.638

5.  Sequential intrastromal corneal ring implantation and cataract surgery in a severe keratoconus patient with cataract.

Authors:  Seung Jae Lee; Hyun Suk Kwon; Il Hwan Koh
Journal:  Korean J Ophthalmol       Date:  2012-05-22

6.  Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study.

Authors:  Evangelia Chalkiadaki; Panos S Gartaganis; Thomas Ntravalias; Ioannis Giannakis; Evangelos Manousakis; Efthymios Karmiris
Journal:  Ther Adv Ophthalmol       Date:  2022-03-31

7.  An innovative approach for determining the customized refractive index of ectatic corneas in cataractous patients.

Authors:  Shiva Pirhadi; Keivan Maghooli; Khosrow Jadidi
Journal:  Sci Rep       Date:  2020-10-07       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.