Literature DB >> 8972328

Bone marrow lesions: evaluation with fat-suppression turbo spin echo MR imaging at 0.5 T.

H Chrysikopoulos1, J Pappas, N Papanikolaou, A Papazoglou, A Roussakis, J Andreou.   

Abstract

The purpose of this study was the assessment of the diagnostic value of fat-suppression T2-weighted images for a variety of bone marrow lesions. We performed 40 studies of the axial or appendicular skeleton in 33 patients (age range 4-80 years) with neoplastic, inflammatory or traumatic lesions with a 0.5 T system (Gyroscan T5, Philips Medical Systems, Best, The Netherlands). Fat-suppression T2-weighted images [turbo spin echo (TSE) with spectral presaturation with inversion recovery (SPIR)] were obtained in addition to the routine T1-weighted SE and T2-weighted TSE sequences. Fat-suppression TSE T2-weighted images were better than standard TSE T2-weighted images in 25 studies. In 11 of them demonstration and characterization of the lesions (known from T1-weighted images) was possible only after fat suppression. In the other 14 patients demonstration of the full extent of the lesion especially to the nearby soft tissues was possible only after fat suppression. In 13 studies no advantage was conferred by SPIR, whereas in two instances T2-weighted images were better. Fat-suppression T2-weighted images are diagnostically useful in a variety of lesions of the musculoskeletal system, but their limitations should be known.

Entities:  

Mesh:

Year:  1996        PMID: 8972328     DOI: 10.1007/bf00240699

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  9 in total

Review 1.  Factors influencing contrast in fast spin-echo MR imaging.

Authors:  R T Constable; A W Anderson; J Zhong; J C Gore
Journal:  Magn Reson Imaging       Date:  1992       Impact factor: 2.546

2.  Fast spin-echo MR imaging of the brain and spine: current concepts.

Authors:  K M Jones; R V Mulkern; R B Schwartz; K Oshio; P D Barnes; F A Jolesz
Journal:  AJR Am J Roentgenol       Date:  1992-06       Impact factor: 3.959

3.  Signal-to-noise and contrast in fast spin echo (FSE) and inversion recovery FSE imaging.

Authors:  R T Constable; R C Smith; J C Gore
Journal:  J Comput Assist Tomogr       Date:  1992 Jan-Feb       Impact factor: 1.826

4.  Clinical applications and methodological developments of the RARE technique.

Authors:  J Hennig; H Friedburg
Journal:  Magn Reson Imaging       Date:  1988 Jul-Aug       Impact factor: 2.546

5.  Fast spin-echo imaging of the knee: factors influencing contrast.

Authors:  D W Piraino; P A Hardy; J P Schils; B J Richmond; J A Tkach; G H Belhobek
Journal:  J Magn Reson Imaging       Date:  1993 Nov-Dec       Impact factor: 4.813

6.  Fast spin-echo MR in the detection of vertebral metastases: comparison of three sequences.

Authors:  K M Jones; R B Schwartz; M T Mantello; S S Ahn; R Khorasani; S Mukherji; K Oshio; R V Mulkern
Journal:  AJNR Am J Neuroradiol       Date:  1994-03       Impact factor: 3.825

7.  MR imaging of bone marrow lesions: relative conspicuousness on T1-weighted, fat-suppressed T2-weighted, and STIR images.

Authors:  S A Mirowitz; P Apicella; W R Reinus; A M Hammerman
Journal:  AJR Am J Roentgenol       Date:  1994-01       Impact factor: 3.959

8.  Bone contusions of the knee: increased lesion detection with fast spin-echo MR imaging with spectroscopic fat saturation.

Authors:  S R Kapelov; L M Teresi; W G Bradley; N R Bucciarelli; D M Murakami; W J Mullin; J E Jordan
Journal:  Radiology       Date:  1993-12       Impact factor: 11.105

9.  Why fat is bright in RARE and fast spin-echo imaging.

Authors:  R M Henkelman; P A Hardy; J E Bishop; C S Poon; D B Plewes
Journal:  J Magn Reson Imaging       Date:  1992 Sep-Oct       Impact factor: 4.813