Literature DB >> 8950685

Comparative evaluation of three assays for the quantitation of human immunodeficiency virus type 1 RNA in plasma.

J Coste1, B Montes, J Reynes, M Peeters, C Segarra, J P Vendrell, E Delaporte, M Segondy.   

Abstract

Reverse transcriptase-coupled polymerase chain reaction (Amplicor HIV-1 Monitor), the branched DNA (bDNA) method (Quantiplex HIV-1 RNA) and the nucleic acid sequence-based assay (NASBA HIV-1 RNA QT) were comparatively evaluated for the quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in plasma. Among 60 plasma specimens from HIV-1 infected patients, HIV-1 RNA was detected in 56 by Amplicor (sensitivity, 93.3%), in 41 by bDNA (sensitivity, 68.3%), and in 60 by NASBA (sensitivity, 100%). HIV-1 RNA was not detected by any of these methods in 34/34 plasma specimens from HIV-1-seronegative blood donors (specificity, 100%). The HIV-1 RNA levels as determined by the different methods were correlated significantly. The frequency of concordant results (log difference < 0.50) was 80.4% between Amplicor and NASBA, 77.5% between Amplicor and bDNA, and 58.6% between bDNA and NASBA. After initiation of antiviral therapy, HIV-1 RNA level variations observed with the three methods were similar. HIV-1 RNA levels were inversely correlated with the CD4+ T cell counts, whereas no correlation was found with HIV-1 p24-antigen levels. When the methods were evaluated for reproducibility, coefficients of variation ranged from 11% to 40% for Amplicor, from 6% to 35% for bDNA, and from 13% to 62% for NASBA. Quantitation of HIV-1 RNA in culture supernatants from HIV-1 subtype A to H strains showed that bDNA can be used to quantitate RNA from all HIV-1 subtypes, whereas Amplicor failed to detect RNA from subtype A strains and NASBA subtype G strains.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8950685     DOI: 10.1002/(SICI)1096-9071(199612)50:4<293::AID-JMV3>3.0.CO;2-3

Source DB:  PubMed          Journal:  J Med Virol        ISSN: 0146-6615            Impact factor:   2.327


  25 in total

1.  Comparative evaluation of two branched-DNA human immunodeficiency virus type 1 RNA quantification assays with lower detection limits of 50 and 500 copies per milliliter.

Authors:  C Manegold; C Krempe; H Jablonowski; L Kajala; M Dietrich; O Adams
Journal:  J Clin Microbiol       Date:  2000-02       Impact factor: 5.948

2.  Obtaining unacceptable results in assays for quantitation of human immunodeficiency virus type 1 RNA in plasma samples.

Authors:  A Aguilera; A Vela; M Treviño; E Varela; R Seoane; B J Regueiro
Journal:  J Clin Microbiol       Date:  2000-01       Impact factor: 5.948

3.  Comparison of levels of human immunodeficiency virus type 1 RNA in plasma as measured by the NucliSens nucleic acid sequence-based amplification and Quantiplex branched-DNA assays.

Authors:  C C Ginocchio; S Tetali; D Washburn; F Zhang; M H Kaplan
Journal:  J Clin Microbiol       Date:  1999-04       Impact factor: 5.948

4.  Improved detection of rhinoviruses by nucleic acid sequence-based amplification after nucleotide sequence determination of the 5' noncoding regions of additional rhinovirus strains.

Authors:  K Loens; M Ieven; D Ursi; C De Laat; P Sillekens; P Oudshoorn; H Goossens
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

5.  Detection of rhinoviruses by tissue culture and two independent amplification techniques, nucleic acid sequence-based amplification and reverse transcription-PCR, in children with acute respiratory infections during a winter season.

Authors:  K Loens; H Goossens; C de Laat; H Foolen; P Oudshoorn; S Pattyn; P Sillekens; M Ieven
Journal:  J Clin Microbiol       Date:  2006-01       Impact factor: 5.948

6.  Prevalence of human immunodeficiency virus type 1 (HIV-1) non-B subtypes in foreigners living in Madrid, Spain, and comparison of the performances of the AMPLICOR HIV-1 MONITOR version 1.0 and the new automated version 1.5.

Authors:  A Holguín; B Aracil; A Alvarez; C Barros; V Soriano
Journal:  J Clin Microbiol       Date:  2001-05       Impact factor: 5.948

7.  Impact of phenotype definition on genome-wide association signals: empirical evaluation in human immunodeficiency virus type 1 infection.

Authors:  Evangelos Evangelou; Jacques Fellay; Sara Colombo; Javier Martinez-Picado; Niels Obel; David B Goldstein; Amalio Telenti; John P A Ioannidis
Journal:  Am J Epidemiol       Date:  2011-04-13       Impact factor: 4.897

8.  Comparative performance of three viral load assays on human immunodeficiency virus type 1 (HIV-1) isolates representing group M (subtypes A to G) and group O: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR version 1.5, and Quantiplex HIV-1 RNA version 3.0.

Authors:  P Swanson; V Soriano; S G Devare; J Hackett
Journal:  J Clin Microbiol       Date:  2001-03       Impact factor: 5.948

9.  Clinical evaluation of an in-house reverse transcription-competitive PCR for quantitation of human immunodeficiency virus type 1 RNA in plasma.

Authors:  M Zazzi; L Romano; M Catucci; G Venturi; A De Milito; P E Valensin
Journal:  J Clin Microbiol       Date:  1999-02       Impact factor: 5.948

10.  Factors associated with HIV-1 proviral DNA loads in patients with undetectable plasma RNA load.

Authors:  Jun Yong Choi; Young Goo Song; Young Hwa Kim; Chang Oh Kim; Myung Soo Kim; Bum Sik Chin; Sang Hoon Han; Suk Hoon Choi; Han Sung Lee; Su Jin Jeong; Heekyoung Choi; June Myung Kim
Journal:  J Korean Med Sci       Date:  2009-02-28       Impact factor: 2.153

View more