Literature DB >> 8947906

Repositioning accuracy of a noninvasive head fixation system for stereotactic radiotherapy.

R J Hamilton1, F T Kuchnir, C A Pelizzari, P J Sweeney, S J Rubin.   

Abstract

We report on the repositioning accuracy of patient setup achieved with a noninvasive head fixation device for stereotactic radiotherapy. A custom head mask which attaches to our stereotactic radiosurgery head ring assembly is fabricated for each patient. The position and orientation of a patient in the stereotatic space at the time of treatment are determined from analyzing portal films containing images of radio-opaque spheres embedded in a custom mouthpiece. From analysis of 104 setups of 12 patients, we find that the average distance between the treated isocenter and its mean position is 1.8 mm, and that the standard deviations of the position of the treated isocenter in stereotactic coordinate space about its mean position are less than 1.4 mm in translation in any direction and less than 1 degree of rotation about any axis.

Entities:  

Mesh:

Year:  1996        PMID: 8947906     DOI: 10.1118/1.597754

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy.

Authors:  Shidong Li; Lawrence R Kleinberg; Daniele Rigamonti; Moody D Wharam; Abdul Rashid; Juan Jackson; David Djajaputra; Shenjen He; Tunisia Creasey; Theodore L DeWeese
Journal:  Technol Cancer Res Treat       Date:  2010-12

2.  Rotational and translational reproducibility of newly developed Leksell frame-based relocatable fixation system.

Authors:  Etsuo Kunieda; Hossain M Deloar; Masayuki Kitamura; Osamu Kawaguchi; Hideyuki Shiba; Atsuya Takeda; Takatsugu Kawase; Satoshi Seki; Naoyuki Shigematsu; Atsushi Kubo
Journal:  Radiat Med       Date:  2006-08

3.  Effect of fiducial marker defects on stereotactic target localization in the Leksell stereotactic system.

Authors:  Jeong-Hoon Park; Jung Ho Han; Chae-Yong Kim; Chang Wan Oh; Dong Gyu Kim; Tae-Suk Suh; Hyun-Tai Chung
Journal:  Med Biol Eng Comput       Date:  2011-04-10       Impact factor: 2.602

4.  Relocatable fixation systems in intracranial stereotactic radiotherapy. Accuracy of serial CT scans and patient acceptance in a randomized design.

Authors:  A Theelen; J Martens; G Bosmans; R Houben; J J Jager; I Rutten; P Lambin; A W Minken; B G Baumert
Journal:  Strahlenther Onkol       Date:  2011-12-24       Impact factor: 3.621

5.  Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomes.

Authors:  Giuseppe Minniti; Claudia Scaringi; Enrico Clarke; Maurizio Valeriani; Mattia Osti; Riccardo Maurizi Enrici
Journal:  Radiat Oncol       Date:  2011-11-16       Impact factor: 3.481

6.  Preliminary Evaluation of a Novel Thermoplastic Mask System with Intra-fraction Motion Monitoring for Future Use with Image-Guided Gamma Knife.

Authors:  Winnie Li; Gregory Bootsma; Oscar Von Schultz; Per Carlsson; Normand Laperriere; Barbara-Ann Millar; David Jaffray; Caroline Chung
Journal:  Cureus       Date:  2016-03-13

7.  Analysis of patient repositioning accuracy in precision radiation therapy using automated image fusion.

Authors:  James L Robar; Brenda G Clark; Jason W Schella; Chang Seon Kim
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

8.  An immobilization and localization technique for SRT and IMRT of intracranial tumors.

Authors:  Leonid B Leybovich; Anil Sethi; Nesrin Dogan; Edward Melian; Mathew Krasin; Bahman Emami
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

9.  Accuracy of relocation, evaluation of geometric uncertainties and clinical target volume (CTV) to planning target volume (PTV) margin in fractionated stereotactic radiotherapy for intracranial tumors using relocatable Gill-Thomas-Cosman (GTC) frame.

Authors:  Saikat Das; Rajesh Isiah; B Rajesh; B Paul Ravindran; Rabi Raja Singh; Selvamani Backianathan; J Subhashini
Journal:  J Appl Clin Med Phys       Date:  2010-12-28       Impact factor: 2.102

10.  CBCT Verification of SRT for Patients With Brain Metastases.

Authors:  Judit Papp; Mihály Simon; Emese Csiki; Árpád Kovács
Journal:  Front Oncol       Date:  2022-01-19       Impact factor: 6.244

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.