Dosimetric characteristics of an improved radiochromic film.

A S Meigooni1, M F Sanders, G S Ibbott, S R Szeglin.   

Abstract

Recently, a new model of radiochromic film has been developed for medical applications to provide a higher sensitivity and better uniformity of response than existing models (i.e., MD-55). Dosimetric characteristics including sensitivity, linearity, reproducibility, uniformity, and dependence on energy and time have been studied experimentally. The characteristics of the new films were compared with those of model MD-55. For these investigations, the two films were exposed to ionizing radiation in the dose range from 1-72 Gy, using gamma-rays from a 60Co teletherapy unit and 6- and 18-MV x rays from a linear accelerator. The response of the exposed film was measured with a helium-neon laser densitometer. The results indicated that the sensitivity of the improved film was about 40% greater than that of MD-55 film. Moreover, the response of the improved film was found to be uniform within 4% only in one direction of the film. The orthogonal direction indicated a nonuniformity of up to 15%, similar to that of model MD-55. Less than 5% energy dependence in the megavoltage photon range was observed for the new film. Complete dosimetric characteristics of the new film are presented.

Entities:  

Mesh:

Year:  1996        PMID: 8947902     DOI: 10.1118/1.597747

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Technical note: Heterogeneity dose calculation accuracy in IMRT: study of five commercial treatment planning systems using an anthropomorphic thorax phantom.

Authors:  Scott E Davidson; Richard A Popple; Geoffrey S Ibbott; David S Followill
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

2.  Measurement verification of dose distributions in pulsed-dose rate brachytherapy in breast cancer.

Authors:  Patrycja Mantaj; Grzegorz Zwierzchowski
Journal:  Rep Pract Oncol Radiother       Date:  2013-04-12

3.  Evaluation of gafchromic EBT film for intensity modulated radiation therapy dose distribution verification.

Authors:  A Sankar; P G Goplakrishna Kurup; V Murali; Komanduri M Ayyangar; R Mothilal Nehru; J Velmurugan
Journal:  J Med Phys       Date:  2006-04

4.  Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification.

Authors:  Valeria Casanova Borca; Massimo Pasquino; Giuliana Russo; Pierangelo Grosso; Domenico Cante; Piera Sciacero; Giuseppe Girelli; Maria Rosa La Porta; Santi Tofani
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

5.  Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films.

Authors:  Sharifeh A Dini; Rafiq A Koona; John R Ashburn; Ali S Meigoonia
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

6.  An anthropomorphic spine phantom for proton beam approval in NCI-funded trials.

Authors:  Jongmin Cho; Paige A Summers; Geoffrey S Ibbott
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

7.  A study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners.

Authors:  G Thomas; R Y L Chu; Frank Rabe
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.