Effects of polar sampling in k-space.

M L Lauzon1, B K Rutt.   

Abstract

Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to aliasing. Here, the Fourier aliasing effects of uniform polar sampling, i.e., equally spaced radial and azimuthal samples, are explained from the principal point spread function (PSF). The principal PSF is determined by assuming equally spaced concentric ring samples in k-space. The radial effects such as replication, smearing, truncation artifacts, and sampling requirements, are characterized based on the PSF.

Mesh:

Year:  1996        PMID: 8946360     DOI: 10.1002/mrm.1910360617

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  On spatially selective RF excitation and its analogy with spiral MR image acquisition.

Authors:  P Börnert; B Aldefeld
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

2.  Improvements in spiral MR imaging.

Authors:  P Börnert; H Schomberg; B Aldefeld; J Groen
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

3.  Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla.

Authors:  Andrew N Priest; P Martin Bansmann; Kai Müllerleile; Gerhard Adam
Journal:  Eur Radiol       Date:  2006-10-05       Impact factor: 5.315

4.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.

Authors:  Dimitris Mitsouras; Robert V Mulkern; Frank J Rybicki
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

5.  Hybrid T2 - and T1 -weighted radial acquisition for free-breathing abdominal examination.

Authors:  Thomas Benkert; John P Mugler; David S Rigie; Daniel K Sodickson; Hersh Chandarana; Kai Tobias Block
Journal:  Magn Reson Med       Date:  2018-04-15       Impact factor: 4.668

6.  Detection of calcifications in vivo and ex vivo after brain injury in rat using SWIFT.

Authors:  Lauri Juhani Lehto; Alejandra Sierra; Curtis Andrew Corum; Jinjin Zhang; Djaudat Idiyatullin; Asla Pitkänen; Michael Garwood; Olli Gröhn
Journal:  Neuroimage       Date:  2012-03-09       Impact factor: 6.556

7.  Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction.

Authors:  Jiayu Song; Yanhui Liu; Sally L Gewalt; Gary Cofer; G Allan Johnson; Qing Huo Liu
Journal:  IEEE Trans Biomed Eng       Date:  2009-01-23       Impact factor: 4.538

8.  Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent.

Authors:  Elizabeth Bucholz; Ketan Ghaghada; Yi Qi; Srinivasan Mukundan; G Allan Johnson
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

9.  Non-cartesian MRI reconstruction with automatic regularization Via Monte-Carlo SURE.

Authors:  Sathish Ramani; Daniel S Weller; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2013-04-12       Impact factor: 10.048

10.  Balanced UTE-SSFP for 19F MR imaging of complex spectra.

Authors:  Matthew J Goette; Jochen Keupp; Jürgen Rahmer; Gregory M Lanza; Samuel A Wickline; Shelton D Caruthers
Journal:  Magn Reson Med       Date:  2014-08-27       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.