Italian experience with AutoCapture in conjunction with a membrane lead. Pacesetter Automatic Control of Energy and Membrane Automatic Threshold Evaluation (Pacemate) Study Group.

S Sermasi1, M Marconi, L Libero, P V Moracchini, L Rusconi, A Mininno, R Sigliano.   

Abstract

AutoCapture is a programmable feature of the Pacesetter Microny SR + 2425T VVIR pacemaker, which provides for the automatic capture verification, increase in output in the presence of noncapture and threshold searching, with adjustment of output settings. The effectiveness of this unit in conjunction with the Membrane models 1400T and 1401T bipolar endocardial leads was studied in 54 patients followed at 19 Italian Centers. The patients were randomized at the time of implantation to receive either the model 1400T or the 1401T lead. The electrodes in these leads are covered by a Nafion membrane, which was either impregnated (model 1400T) or not-impregnated (model 1401T) with steroid. This paper reports the data collected over the first six weeks postimplantation. The results of the automatic capture function was compared to the capture threshold measured using the Vario technique at the time of predischarge evaluations, and weeks 1,2, and 6 of postimplant follow-up. The reliability and effectiveness of the pulse generator-lead system allowed for consistent pacing at very low outputs and safety preserved at a programmed output only 0.3 V above the capture threshold.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8945044     DOI: 10.1111/j.1540-8159.1996.tb03228.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

Review 1.  Threshold tracking pacing based on beat by beat evoked response detection: clinical benefits and potential problems.

Authors:  F Duru; U Bauersfeld; H Schüller; R Candinas
Journal:  J Interv Card Electrophysiol       Date:  2000-10       Impact factor: 1.900

2.  Successful implantation of a bipolar epicardial lead and an autocapture pacemaker in a low-body-weight infant with congenital atrioventricular block: report of a case.

Authors:  Y Tomita; Y Imoto; R Tominaga; H Yasui
Journal:  Surg Today       Date:  2000       Impact factor: 2.549

3.  Impact of automatic adjustment of stimulation outputs on pacemaker longevity in a new dual-chamber pacing system.

Authors:  Christiane Brockes; Mariette Rahn-Schönbeck; Firat Duru; Reto Candinas; Marko Turina
Journal:  J Interv Card Electrophysiol       Date:  2003-02       Impact factor: 1.900

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.