Validation study of a new transit time ultrasonic flow probe for continuous great vessel measurements.

D A Dean1, C X Jia, S E Cabreriza, D A D'Alessandro, M L Dickstein, M J Sardo, N Chalik, H M Spotnitz.   

Abstract

Continuous measurement of cardiac output is important during experimental and clinical cardiac surgery as an indicator of ventricular function. Previous flow probes underestimated flow secondary to position and flow (S-series probes; Transonic Systems, Inc., Ithaca, NY), required frequent calibrations (electromagnetic), and were cumbersome to use. The new A-series probe (ASP) by Transonic Systems, Inc., uses a new X method of ultrasonic illumination insensitive to perturbations in flow. The ASPs were found to be accurate during in vitro studies, but have not been validated in vivo. Six anesthetized pigs were instrumented for right atrium to left atrium bypass, and ASPs were placed on the ascending aorta and pulmonary artery. Baseline measurements included aortic (Ao) and pulmonic flow (P), and thermodilution (Td) cardiac output. Animals then were placed on right heart bypass, and flow was randomly varied from 1 to 6 L/min, and Ao flow was recorded. In addition, ASPs were rotated and their direction reversed. After data collection, the occlusive roller pump (RP) was calibrated using a timed collection method. Calibrated RP flows were plotted versus ASP flows, and regression was applied. There was no difference between mean Ao, P, and Td cardiac outputs at baseline. In addition, changes in position and direction of the probe did not affect measurement of flow. The ASPs showed a highly linear correlation with RP ([r = 0.98, p < 0.01] ASP[L/min] = 0.98 RP-0.032). During laminar flow states, ASPs are accurate and insensitive to position on the great vessels.

Entities:  

Mesh:

Year:  1996        PMID: 8944965     DOI: 10.1097/00002480-199609000-00072

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  14 in total

1.  Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system.

Authors:  Stéphane Thierry; Dominique Thebert; Elsa Brocas; Fereshte Razzaghi; Andry Van De Louw; Daniel Loisance; Jean Louis Teboul
Journal:  Intensive Care Med       Date:  2003-09-10       Impact factor: 17.440

2.  An assessment of the accuracy of renal blood flow estimation by Doppler ultrasound.

Authors:  Li Wan; Natalie Yang; Chee-Yan Hiew; Anthony Schelleman; Lynne Johnson; Clive May; Rinaldo Bellomo
Journal:  Intensive Care Med       Date:  2008-04-12       Impact factor: 17.440

3.  Altered cardiovascular function at birth in growth-restricted preterm lambs.

Authors:  Graeme R Polglase; Beth J Allison; Elise Coia; Anqi Li; Graham Jenkin; Atul Malhotra; Arvind Sehgal; Martin Kluckow; Andrew W Gill; Stuart B Hooper; Suzanne L Miller
Journal:  Pediatr Res       Date:  2016-05-16       Impact factor: 3.756

4.  Clinical validation of a real-time data processing system for cardiac output and arterial pressure measurement during intraoperative biventricular pacing optimization.

Authors:  Christopher K Johnson; Santos E Cabreriza; Rana L Sahar; Alexander Rusanov; Daniel Y Wang; Bin Cheng; Mira S Gendy; T Alexander Quinn; Henry Michael Spotnitz
Journal:  ASAIO J       Date:  2012 May-Jun       Impact factor: 2.872

5.  Hemodynamic and metabolic effects of a new pediatric dobutamine formulation in hypoxic newborn pigs.

Authors:  Victoria E Mielgo; Adolf Valls-I-Soler; Juan M Lopez-de-Heredia; Heike Rabe; Carmen Rey-Santano
Journal:  Pediatr Res       Date:  2016-11-25       Impact factor: 3.756

6.  Quantitative Assessment of Renal Perfusion and Oxygenation by Invasive Probes: Basic Concepts.

Authors:  Kathleen Cantow; Roger G Evans; Dirk Grosenick; Thomas Gladytz; Thoralf Niendorf; Bert Flemming; Erdmann Seeliger
Journal:  Methods Mol Biol       Date:  2021

7.  Cardiac output measurement by arterial pressure waveform analysis during optimization of biventricular pacing after cardiac surgery.

Authors:  Justin H Booth; T Alexander Quinn; Marc E Richmond; Santos E Cabreriza; Alan D Weinberg; Taylor Johnston; Henry M Spotnitz
Journal:  ASAIO J       Date:  2009 Nov-Dec       Impact factor: 2.872

8.  Use of Larger Species such as Dog and Pig as Model Systems to Study Cardiac Disease.

Authors:  B A Coppola; J H Omens
Journal:  Drug Discov Today Dis Models       Date:  2009-10-01

9.  Pulmonary Artery Catheter (PAC) Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM): An Ovine Cardiac Output Validation.

Authors:  Robert A Phillips; Sally G Hood; Beverley M Jacobson; Malcolm J West; Li Wan; Clive N May
Journal:  Crit Care Res Pract       Date:  2012-05-09

10.  Angiotensin II in experimental hyperdynamic sepsis.

Authors:  Li Wan; Christoph Langenberg; Rinaldo Bellomo; Clive N May
Journal:  Crit Care       Date:  2009-11-30       Impact factor: 9.097

View more