Literature DB >> 19770798

Cardiac output measurement by arterial pressure waveform analysis during optimization of biventricular pacing after cardiac surgery.

Justin H Booth1, T Alexander Quinn, Marc E Richmond, Santos E Cabreriza, Alan D Weinberg, Taylor Johnston, Henry M Spotnitz.   

Abstract

Biventricular pacing (BiVP) can optimize cardiac output (CO) in patients after cardiac surgery, so devices that calculate continuous CO from arterial pressure may be a useful tool. We investigated PulseCO for measuring CO during optimization by comparison with aortic flow probe measurement. Seven patients in the Biventricular Pacing After Cardiac Surgery (BiPACS) trial were studied. Before weaning from cardiopulmonary bypass, BiVP was initiated. After bypass, CO was optimized by varying atrioventricular pacing delay, ventricular site, and interventricular pacing delay with a randomized protocol. Continuous CO was measured by PulseCO and aortic flow probe. Reliability was estimated by Fleiss method and agreement assessed by Bland-Altman analysis. Compared with flow probe, PulseCO reliably measured changes in CO (intraclass correlation coefficient = 0.90) but underestimated the change (-4% + or - 17%). In contrast, changes in mean arterial pressure did not reflect changes in CO (intraclass correlation coefficient = 0.02). Thus, PulseCO can measure continuous CO in open-chest patients after cardiac surgery, whereas underestimating changes occurring across 10-second pacemaker changes. Further studies in the closed chest are indicated.

Entities:  

Mesh:

Year:  2009        PMID: 19770798      PMCID: PMC2783470          DOI: 10.1097/MAT.0b013e3181bbafd5

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  29 in total

1.  Validation of mean arterial pressure as an indicator of acute changes in cardiac output.

Authors:  Jason E Prasso; George Berberian; Santos E Cabreriza; T Alexander Quinn; Lauren J Curtis; David G Rabkin; Alan D Weinberg; Henry M Spotnitz
Journal:  ASAIO J       Date:  2005 Jan-Feb       Impact factor: 2.872

2.  Validation study of PulseCO system for continuous cardiac output measurement.

Authors:  George Berberian; T Alexander Quinn; Deon W Vigilance; David Y Park; Santos E Cabreriza; Lauren J Curtis; Henry M Spotnitz
Journal:  ASAIO J       Date:  2005 Jan-Feb       Impact factor: 2.872

3.  Validation study of a new transit time ultrasonic flow probe for continuous great vessel measurements.

Authors:  D A Dean; C X Jia; S E Cabreriza; D A D'Alessandro; M L Dickstein; M J Sardo; N Chalik; H M Spotnitz
Journal:  ASAIO J       Date:  1996 Sep-Oct       Impact factor: 2.872

4.  Estimation of stroke volume in the dog by a pulse contour method.

Authors:  N T Kouchoukos; L C Sheppard; D A McDonald
Journal:  Circ Res       Date:  1970-05       Impact factor: 17.367

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Fentanyl augments the blockade of the sympathetic response to incision (MAC-BAR) produced by desflurane and isoflurane: desflurane and isoflurane MAC-BAR without and with fentanyl.

Authors:  M Daniel; R B Weiskopf; M Noorani; E I Eger
Journal:  Anesthesiology       Date:  1998-01       Impact factor: 7.892

7.  Reflected pressure waves in the ascending aorta: effect of glyceryl trinitrate.

Authors:  D H Fitchett; G J Simkus; J P Beaudry; D G Marpole
Journal:  Cardiovasc Res       Date:  1988-07       Impact factor: 10.787

8.  Anesthetic doses blocking adrenergic (stress) and cardiovascular responses to incision--MAC BAR.

Authors:  M F Roizen; R W Horrigan; B M Frazer
Journal:  Anesthesiology       Date:  1981-05       Impact factor: 7.892

9.  Effect of nitroglycerin on aortic impedance, diameter, and pulse-wave velocity.

Authors:  T W Latson; W C Hunter; N Katoh; K Sagawa
Journal:  Circ Res       Date:  1988-05       Impact factor: 17.367

Review 10.  Early goal-directed therapy: an evidence-based review.

Authors:  Andrew Rhodes; E David Bennett
Journal:  Crit Care Med       Date:  2004-11       Impact factor: 7.598

View more
  2 in total

1.  Real-time stroke volume measurements for the optimization of cardiac resynchronization therapy parameters.

Authors:  José M Dizon; T Alexander Quinn; Santos E Cabreriza; Daniel Wang; Henry M Spotnitz; Kathleen Hickey; Hasan Garan
Journal:  Europace       Date:  2010-06-04       Impact factor: 5.214

2.  Simultaneous variation of ventricular pacing site and timing with biventricular pacing in acute ventricular failure improves function by interventricular assist.

Authors:  T Alexander Quinn; Santos E Cabreriza; Marc E Richmond; Alan D Weinberg; Jeffrey W Holmes; Henry M Spotnitz
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-10-23       Impact factor: 4.733

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.