In vivo observation of cavitation on prosthetic heart valves.

C M Zapanta1, D R Stinebring, D S Sneckenberger, S Deutsch, D B Geselowitz, J M Tarbell, A J Synder, G Rosenberg, W J Weiss, W E Pae, W S Pierce.   

Abstract

In this study, a method to determine the existence of prosthetic heart valve cavitation in vivo is presented. Pennsylvania State University Left Ventricular Assist Devices (LVADs) were implanted in two separate calves for this study. Björk-Shiley Monostrut (Irvine, CA) 27 mm and 25 mm valves with Delrin occluders were used in the mitral and aortic positions, respectively. A high fidelity, piezoelectric pressure transducer was mounted approximately 1.25 cm proximal to the mitral valve and measured the high frequency pressure fluctuations caused by cavitation bubble formation and collapse after valve closure. The root mean square (RMS) value of the mitral pressure signal during a 5 ms interval after valve closure was used as a measure of cavitation intensity. The pressure signals observed in vivo were similar to ones observed in vitro with the same type of pressure transducer and were associated with the visually observed cavitation. The percentage of beats with cavitation increased from 20.3% to 67.7% when pump filling was decreased by increasing beat rate. A blood test conducted during post-operative days 1-3 showed a significant increase in plasma hemoglobin during the low filling condition. However, blood tests conducted later (post-operative days 7-44) did not show a significant change in plasma hemoglobin during low filling conditions.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8944940     DOI: 10.1097/00002480-199609000-00047

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  7 in total

1.  Near valve flows and potential blood damage during closure of a bileaflet mechanical heart valve.

Authors:  L H Herbertson; S Deutsch; K B Manning
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

Review 2.  Cavitation in medicine.

Authors:  Christopher Earls Brennen
Journal:  Interface Focus       Date:  2015-10-06       Impact factor: 3.906

3.  Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing.

Authors:  Hwansung Lee; Akihiko Homma; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

4.  Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing.

Authors:  Hwansung Lee; Akihiko Homma; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2010-02-13       Impact factor: 1.731

5.  Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device.

Authors:  Hwansung Lee; Eiki Akagawa; Akihiko Homma; Tomonori Tsukiya; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2007-09-20       Impact factor: 1.731

6.  Special Issue on Professor John M. Tarbell's Contribution to Cardiovascular Engineering.

Authors:  Hanjoong Jo; Keefe Manning; John M Tarbell
Journal:  Cardiovasc Eng Technol       Date:  2021-01-07       Impact factor: 2.495

7.  A Single-opening&closing Valve Tester for Direct Measurement of Closing Volume of the Heart Valve.

Authors:  Hao Wang; Zhan Cui; Zhongxi Zhou; Zhaoming He
Journal:  Cardiovasc Eng Technol       Date:  2021-06-25       Impact factor: 2.495

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.