Literature DB >> 8915911

Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures.

C P Comstock1, M C van der Meulen, S B Goodman.   

Abstract

Early reduction and rigid fixation of unstable vertical shear pelvic fractures has been shown to decrease the incidence of late sequelae and facilitate early mobilization. The results of fixation of the posterior pelvic ring without anterior fixation are unknown. The purpose of this study was to perform a biomechanical comparison of the most frequently used techniques of posterior fixation for unstable pelvic sacroiliac dislocations in conjunction with ipsilateral rami fractures, i.e., an unstable vertical shear injury. The four methods of posterior fixation tested included sacroiliac (SI) screws, anterior SI plates, transiliac bars, and a combination of SI screws and transiliac bars. Six cadaveric pelvises were tested in axial compression and torsion on a biaxial servohydraulic testing machine. Compared to the intact pelvis, single posterior methods of fixation provided approximately 70-85% resistance to axial and torsional loading. By combining SI screws with transiliac bars, approximately 90% of intact pelvic stability was achieved. Our results suggest that rigid posterior fixation of sacroiliac dislocations alone may obviate the need for additional complex anterior surgical procedures to fix rami fractures.

Entities:  

Mesh:

Year:  1996        PMID: 8915911     DOI: 10.1097/00005131-199611000-00001

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  20 in total

1.  Two-stage surgical procedure for treating pelvic malunions.

Authors:  Marc-Antoine Rousseau; Frédéric Laude; Jean-Yves Lazennec; Gérard Saillant; Yves Catonné
Journal:  Int Orthop       Date:  2006-03-28       Impact factor: 3.075

2.  Biomechanical evaluation of supplemental percutaneous lumbo-sacro-iliac screws for spinopelvic fixation following total sacrectomy.

Authors:  Vu H Le; Nathanael Heckmann; Nickul Jain; Lawrence Wang; Alexander W L Turner; Thay Q Lee; S Samuel Bederman
Journal:  J Spinal Disord Tech       Date:  2015-05

3.  Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation.

Authors:  S A Khaled; O Soliman; M A Wahed
Journal:  Eur J Trauma Emerg Surg       Date:  2014-10-21       Impact factor: 3.693

4.  Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone.

Authors:  Jonathan M Vigdorchik; Amanda O Esquivel; Xin Jin; King H Yang; Rahul Vaidya
Journal:  Int Orthop       Date:  2013-05-04       Impact factor: 3.075

5.  Fully threaded sacroiliac lag screws have higher load to failure when compared to partially threaded screws: A biomechanical study.

Authors:  Huai Ming Phen; Brent Wise; Daniel Thompson; Jason Nascone; Adam Boissonneault; Michael Maceroli
Journal:  J Clin Orthop Trauma       Date:  2020-10-19

6.  Minimally invasive stabilisation of posterior pelvic-ring instabilities with a transiliac locked compression plate.

Authors:  Philipp Kobbe; Ingrid Hockertz; Richard M Sellei; Heinrich Reilmann; Thomas Hockertz
Journal:  Int Orthop       Date:  2011-05-31       Impact factor: 3.075

Review 7.  [Biomechanical principles for treatment of osteoporotic fractures of the pelvis].

Authors:  A Gänsslen
Journal:  Unfallchirurg       Date:  2010-04       Impact factor: 1.000

8.  Biomechanical study of the sacroiliac fracture fixation with titanium rods and pedicle screws.

Authors:  Fabrício Hidetoshi Ueno; Marina Justi Pisani; André Nunes Machado; Fábio Lucas Rodrigues; Edison Noburo Fujiki; Luciano Miller Reis Rodrigues
Journal:  Acta Ortop Bras       Date:  2015 May-Jun       Impact factor: 0.513

9.  Investigation of pelvic symmetry using CAD software.

Authors:  Maha S Ead; Kajsa K Duke; Jacob L Jaremko; Lindsey Westover
Journal:  Med Biol Eng Comput       Date:  2019-11-19       Impact factor: 2.602

10.  Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model.

Authors:  Georg Osterhoff; Andrew E Dodd; Florence Unno; Angus Wong; Shahram Amiri; Kelly A Lefaivre; Pierre Guy
Journal:  Clin Orthop Relat Res       Date:  2016-06-22       Impact factor: 4.176

View more