Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model.

Georg Osterhoff1, Andrew E Dodd2, Florence Unno2, Angus Wong2, Shahram Amiri2, Kelly A Lefaivre2, Pierre Guy2.   

Abstract

BACKGROUND: Sacroiliac screw fixation in elderly patients with pelvic fractures is prone to failure owing to impaired bone quality. Cement augmentation has been proposed as a possible solution, because in other anatomic areas this has been shown to reduce screw loosening. However, to our knowledge, this has not been evaluated for sacroiliac screws. QUESTIONS/PURPOSES: We investigated the potential biomechanical benefit of cement augmentation of sacroiliac screw fixation in a cadaver model of osteoporotic bone, specifically with respect to screw loosening, construct survival, and fracture-site motion.
METHODS: Standardized complete sacral ala fractures with intact posterior ligaments in combination with ipsilateral upper and lower pubic rami fractures were created in osteoporotic cadaver pelves and stabilized by three fixation techniques: sacroiliac (n = 5) with sacroiliac screws in S1 and S2, cemented (n = 5) with addition of cement augmentation, and transsacral (n = 5) with a single transsacral screw in S1. A cyclic loading protocol was applied with torque (1.5 Nm) and increasing axial force (250-750 N). Screw loosening, construct survival, and sacral fracture-site motion were measured by optoelectric motion tracking. A sample-size calculation revealed five samples per group to be required to achieve a power of 0.80 to detect 50% reduction in screw loosening.
RESULTS: Screw motion in relation to the sacrum during loading with 250 N/1.5 Nm was not different among the three groups (sacroiliac: 1.2 mm, range, 0.6-1.9; cemented: 0.7 mm, range, 0.5-1.3; transsacral: 1.1 mm, range, 0.6-2.3) (p = 0.940). Screw subsidence was less in the cemented group (3.0 mm, range, 1.2-3.7) compared with the sacroiliac (5.7 mm, range, 4.7-10.4) or transsacral group (5.6 mm, range, 3.8-10.5) (p = 0.031). There was no difference with the numbers available in the median number of cycles needed until failure; this was 2921 cycles (range, 2586-5450) in the cemented group, 2570 cycles (range, 2500-5107) for the sacroiliac specimens, and 2578 cycles (range, 2540-2623) in the transsacral group (p = 0.153). The cemented group absorbed more energy before failure (8.2 × 105 N*cycles; range, 6.6 × 105-22.6 × 105) compared with the transsacral group (6.5 × 105 N*cycles; range, 6.4 × 105-6.7 × 105) (p = 0.016). There was no difference with the numbers available in terms of fracture site motion (sacroiliac: 2.9 mm, range, 0.7-5.4; cemented: 1.2 mm, range, 0.6-1.9; transsacral: 2.1 mm, range, 1.2-4.8). Probability values for all between-group comparisons were greater than 0.05.
CONCLUSIONS: The addition of cement to standard sacroiliac screw fixation seemed to change the mode and dynamics of failure in this cadaveric mechanical model. Although no advantages to cement were observed in terms of screw motion or cycles to failure among the different constructs, a cemented, two-screw sacroiliac screw construct resulted in less screw subsidence and greater energy absorbed to failure than an uncemented single transsacral screw. CLINICAL RELEVANCE: In osteoporotic bone, the addition of cement to sacroiliac screw fixation might improve screw anchorage. However, larger mechanical studies using these findings as pilot data should be performed before applying these preliminary findings clinically.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27334321      PMCID: PMC5052190          DOI: 10.1007/s11999-016-4934-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  45 in total

1.  Internal fixation in postpartum symphysis pubis rupture: report of three cases.

Authors:  P M Rommens
Journal:  J Orthop Trauma       Date:  1997-05       Impact factor: 2.512

2.  Stabilization of fatigue fractures of the dorsal pelvis with a trans-sacral bar. Operative technique and outcome.

Authors:  Isabella Mehling; Martin Henry Hessmann; Pol Maria Rommens
Journal:  Injury       Date:  2011-09-01       Impact factor: 2.586

3.  Indications for anterior fixation of pelvic fractures.

Authors:  J M Matta
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

4.  Effect of calcium triphosphate cement on proximal humeral fracture osteosynthesis: a cadaveric biomechanical study.

Authors:  Jim Kennedy; Diarmuid Molony; Neil G Burke; David FitzPatrick; Hannan Mullett
Journal:  J Orthop Surg (Hong Kong)       Date:  2013-08       Impact factor: 1.118

5.  Do Transsacral-transiliac Screws Across Uninjured Sacroiliac Joints Affect Pain and Functional Outcomes in Trauma Patients?

Authors:  John Heydemann; Braden Hartline; Mary Elizabeth Gibson; Catherine G Ambrose; John W Munz; Matthew Galpin; Timothy S Achor; Joshua L Gary
Journal:  Clin Orthop Relat Res       Date:  2016-06       Impact factor: 4.176

6.  Biomechanical comparison of three methods of sacral fracture fixation in osteoporotic bone.

Authors:  Simon C Mears; Edward G Sutter; Simon J Wall; David M Rose; Stephen M Belkoff
Journal:  Spine (Phila Pa 1976)       Date:  2010-05-01       Impact factor: 3.468

7.  OTA highlight paper predicting future displacement of nonoperatively managed lateral compression sacral fractures: can it be done?

Authors:  Brandon Bruce; Mark Reilly; Steven Sims
Journal:  J Orthop Trauma       Date:  2011-09       Impact factor: 2.512

8.  Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients.

Authors:  Kimihiko Sawakami; Akiyoshi Yamazaki; Seiichi Ishikawa; Takui Ito; Kei Watanabe; Naoto Endo
Journal:  J Spinal Disord Tech       Date:  2012-04

9.  Long-term results of the augmented PFNA: a prospective multicenter trial.

Authors:  C Kammerlander; H Doshi; F Gebhard; A Scola; C Meier; W Linhart; M Garcia-Alonso; J Nistal; M Blauth
Journal:  Arch Orthop Trauma Surg       Date:  2013-12-03       Impact factor: 3.067

10.  Cement augmentation of the navigated iliosacral screw in the treatment of insufficiency fractures of the sacrum: a new method using modified implants.

Authors:  Dirk Wähnert; Michale J Raschke; Thomas Fuchs
Journal:  Int Orthop       Date:  2013-04-04       Impact factor: 3.075

View more
  12 in total

1.  CT-based evaluation of volumetric bone density in fragility fractures of the pelvis-a matched case-control analysis.

Authors:  D Schönenberg; R Guggenberger; D Frey; H-C Pape; H-P Simmen; G Osterhoff
Journal:  Osteoporos Int       Date:  2017-11-13       Impact factor: 4.507

2.  [Course of operative treatment of a sacral insufficiency fracture : Successful or serious treatment?]

Authors:  A Lattauschke; F Klauke; B W Ullrich; G O Hofmann; T Mendel
Journal:  Unfallchirurg       Date:  2017-10       Impact factor: 1.000

3.  Effect of Iliosacral Screw Implantation Through a New Channel in Three-Dimensional Printing Pelvic Model.

Authors:  Yunhong Ma; Jian Wang; Qudong Yin; Yu Liu; Dong Li; Yongwei Wu
Journal:  Indian J Orthop       Date:  2021-07-29       Impact factor: 1.033

4.  Operative management of fragility fractures of the pelvis - a systematic review.

Authors:  Daniel G G Wilson; Joshua Kelly; Mark Rickman
Journal:  BMC Musculoskelet Disord       Date:  2021-08-21       Impact factor: 2.362

5.  In-screw polymethylmethacrylate-augmented sacroiliac screw for the treatment of fragility fractures of the pelvis: a prospective, observational study with 1-year follow-up.

Authors:  Andreas Höch; Philipp Pieroh; Ralf Henkelmann; Christoph Josten; Jörg Böhme
Journal:  BMC Surg       Date:  2017-12-08       Impact factor: 2.102

6.  Is cement-augmented sacroiliac screw fixation with partially threaded screws superior to that with fully threaded screws concerning compression and pull-out force in fragility fractures of the sacrum? - a biomechanical analysis.

Authors:  Juliana Hack; Maiwand Safi; Martin Bäumlein; Julia Lenz; Christopher Bliemel; Steffen Ruchholtz; Ludwig Oberkircher
Journal:  BMC Musculoskelet Disord       Date:  2021-12-10       Impact factor: 2.362

7.  Comparison of lumbopelvic fixation and iliosacral screw fixation for the treatment of bilateral sacral fractures.

Authors:  Katharina E Wenning; Emre Yilmaz; Thomas A Schildhauer; Martin F Hoffmann
Journal:  J Orthop Surg Res       Date:  2021-10-16       Impact factor: 2.359

8.  Three-dimensional digital anatomical measurement of modified sacroiliac screws.

Authors:  Tingguang Wang; Bei Zhao; Jun Yan; Jia Wang; Chong Chen; Weidong Mu
Journal:  J Orthop Surg Res       Date:  2022-03-04       Impact factor: 2.359

9.  A feasibility study of individual 3D-printed navigation template for the deep external fixator pin position on the iliac crest.

Authors:  Bin Liang; Qiang Chen; Shuai Liu; Shuo Chen; Qingqiang Yao; Bo Wei; Yan Xu; Cheng Tang; Liming Wang
Journal:  BMC Musculoskelet Disord       Date:  2020-07-21       Impact factor: 2.362

10.  Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study.

Authors:  Moritz F Lodde; J Christoph Katthagen; Clemens O Schopper; Ivan Zderic; R Geoff Richards; Boyko Gueorguiev; Michael J Raschke; René Hartensuer
Journal:  Medicina (Kaunas)       Date:  2021-12-16       Impact factor: 2.430