Literature DB >> 8899271

Clinical outcomes following penetrating keratoplasty using the Barron-Hessburg and Hanna corneal trephination systems.

G A Wilbanks1, S Cohen, M Chipman, D S Rootman.   

Abstract

Two corneal suction trephination systems currently in use are the Barron-Hessburg and the Hanna trephine. This study assessed the outcome of patients who received penetrating keratoplasty using these two systems. One hundred twenty-four eyes (62 with the Hanna system, 62 with the Barron-Hessburg system) from 98 patients undergoing penetrating keratoplasty were evaluated retrospectively. Best corrected spectacle acuity and corneal astigmatism were assessed 6 and 12 months after surgery. No significant difference was noted between the groups 6 months after surgery. At 12 months, a significant improvement in spectacle acuity was present with 55% of the Hanna group having visual acuity of 20/40 or better compared with 33% of the Barron-Hessburg group (p < 0.005). This difference was greater if eyes having the best visual prognoses were separately evaluated: 74% of the Hanna group had 20/40 vision or better compared with 41% of the Barron-Hessburg group (p < 0.005). In eyes having a good visual prognosis, a significant improvement in visual acuity was present, with 33% of the Hanna group improving nine or more lines compared with 9% of the Barron-Hessburg group (p < 0.05). Postoperative keratometric and refractive astigmatism were not different at 6 or 12 months. We found that visual recovery at 1 year is better using the Hanna system, especially in eyes with good visual prognoses.

Entities:  

Mesh:

Year:  1996        PMID: 8899271

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  5 in total

1.  Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes.

Authors:  Milenko Stojkovic; Berthold Seitz; Michael Küchle; Achim Langenbucher; Arne Viestenz; Anja Viestenz; Carmen Hofmann-Rummelt; Gottfried O H Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-17       Impact factor: 3.117

2.  [Non-contact donor cornea trephination with a flying spot excimer laser system].

Authors:  M Müller; Z Sherif; U Pleyer; C Hartmann
Journal:  Ophthalmologe       Date:  2005-02       Impact factor: 1.059

3.  Configuration of recipient corneal cut after mechanical trephination in keratoconus.

Authors:  Sepehr Feizi; Maryam Najafi; Mohammad Ali Javadi; Amir A Azari
Journal:  Int Ophthalmol       Date:  2019-04-09       Impact factor: 2.031

4.  Comparison of Hanna and Hessburg-Barron trephine and punch systems using histological, anterior segment optical coherence tomography, and elliptical curve fitting models.

Authors:  Majid Moshirfar; Charles M Calvo; Krista I Kinard; Lloyd B Williams; Shameema Sikder; Marcus C Neuffer
Journal:  Clin Ophthalmol       Date:  2011-08-12

5.  Accuracy of corneal trephination depth using the Moria single-use adjustable depth vacuum trephine system.

Authors:  Carlton R Fenzl; Adam J Gess; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2014-11-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.