Literature DB >> 8898248

Acoustic and articulatory measures of sibilant production with and without auditory feedback from a cochlear implant.

M L Matthies1, M Svirsky, J Perkell, H Lane.   

Abstract

The articulator positions of a subject with a cochlear implant were measured with an electromagnetic midsagittal articulometer (EMMA) system with and without auditory feedback available to the subject via his implant. Acoustic analysis of sibilant productions included specific measures of their spectral properties as well as the F3 formant amplitude. More general postural characteristics of the utterances, such as speech rate and sound level, were measured as well. Because of the mechanical and aerodynamic interdependence of the articulators, the postural variables must be considered before attributing speech improvement to the selective correction of a phonemic target with the use of auditory feedback. The tongue blade position was related to the shape and central tendency of the /integral of/ spectra; however, changes in the spectral contrast between /s/ and /integral of/ were not related to changes in the more general postural variables of rate and sound level. These findings suggest that the cochlear implant is providing this subject with important auditory cues that he can use to monitor his speech and maintain the phonemic contrast between /s/ and /integral of/.

Mesh:

Year:  1996        PMID: 8898248     DOI: 10.1044/jshr.3905.936

Source DB:  PubMed          Journal:  J Speech Hear Res        ISSN: 0022-4685


  4 in total

1.  Movement goals and feedback and feedforward control mechanisms in speech production.

Authors:  Joseph S Perkell
Journal:  J Neurolinguistics       Date:  2010-03-26       Impact factor: 1.710

2.  Perception and production of /r/ allophones improve with hearing from a cochlear implant.

Authors:  Melanie L Matthies; Frank H Guenther; Margaret Denny; Joseph S Perkell; Ellen Burton; Jennell Vick; Harlan Lane; Mark Tiede; Majid Zandipour
Journal:  J Acoust Soc Am       Date:  2008-11       Impact factor: 1.840

3.  The Lombard effect observed in speech produced by cochlear implant users in noisy environments: A naturalistic study.

Authors:  Jaewook Lee; Hussnain Ali; Ali Ziaei; Emily A Tobey; John H L Hansen
Journal:  J Acoust Soc Am       Date:  2017-04       Impact factor: 1.840

4.  Plasticity in primary auditory cortex of monkeys with altered vocal production.

Authors:  Steven W Cheung; Srikantan S Nagarajan; Christoph E Schreiner; Purvis H Bedenbaugh; Andrew Wong
Journal:  J Neurosci       Date:  2005-03-09       Impact factor: 6.167

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.