Literature DB >> 8897026

Torque, total work, power, torque acceleration energy and acceleration time assessed on a dynamometer: reliability of knee and elbow extensor and flexor strength measurements.

O R Madsen1.   

Abstract

Isometric torque and isokinetic peak torque, total work, power, torque acceleration energy and acceleration time at 30, 120 and 240 degrees.s-1 of the knee and elbow extensors and flexors were measured using an isokinetic dynamometer in 24 healthy women. Intrasession variation of the measurements was evaluated and the short-term and long-term reliability was assessed by repeating all procedures after averages of 2 and 30 days, respectively. The effect of learning on peak torque during a session was also evaluated. Moreover, the effect of general warming-up on knee extensor and flexor strength was examined on a separate day. Using correlations, numerous studies have indicated that muscle strength measurements are reliable. Correlations, however, are inappropriate and misleading in studies on reliability. In the present study reliability of each strength variable was expressed as the coefficient of variation (CV). With the protocol used, neither learning nor warming-up had any significant effect on strength. As expected, intra-session variation tended to be less than short-term and long-term inter-session variation. The CVs for strength variables measured 30 days apart exceeded 5% for all variables and rose to 107% for acceleration time. Substantial between-subject variation of individual CVs were found. The study demonstrated that muscle strength measurements may be highly unreliable in the individual subject.

Entities:  

Mesh:

Year:  1996        PMID: 8897026     DOI: 10.1007/bf00377442

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  16 in total

1.  Effect of instructions on isokinetic trunk strength testing variability, reliability, absolute value, and predictive validity.

Authors:  L Matheson; V Mooney; V Caiozzo; G Jarvis; J Pottinger; C DeBerry; K Backlund; K Klein; J Antoni
Journal:  Spine (Phila Pa 1976)       Date:  1992-08       Impact factor: 3.468

2.  Normality, variability and predictability of work, power and torque acceleration energy with respect to peak torque in isokinetic muscle testing.

Authors:  P Kannus
Journal:  Int J Sports Med       Date:  1992-04       Impact factor: 3.118

3.  Isokinetic limb and trunk muscle performance testing: short-term reliability.

Authors:  A L Friedlander; J E Block; N N Byl; H A Stubbs; H S Sadowsky; H K Genant
Journal:  J Orthop Sports Phys Ther       Date:  1991       Impact factor: 4.751

4.  Validity and Reliability of the LIDO Active Isokinetic System.

Authors:  L A Patterson; W E Spivey
Journal:  J Orthop Sports Phys Ther       Date:  1992       Impact factor: 4.751

5.  Assessment of extensor and flexor strength in the individual gonarthrotic patient: interpretation of performance changes.

Authors:  O R Madsen; C Brot
Journal:  Clin Rheumatol       Date:  1996-03       Impact factor: 2.980

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Intramachine and intermachine reliability for selected dynamic muscle performance tests.

Authors:  W D Bandy; S McLaughlin
Journal:  J Orthop Sports Phys Ther       Date:  1993-11       Impact factor: 4.751

8.  Short-term and long-term intra-individual variations and critical differences of haematological laboratory parameters.

Authors:  G M Costongs; P C Janson; B M Bas; J Hermans; P J Brombacher; J W van Wersch
Journal:  J Clin Chem Clin Biochem       Date:  1985-02

9.  Reliability of isokinetic muscle strength testing in 45- to 78-year-old men and women.

Authors:  W R Frontera; V A Hughes; G E Dallal; W J Evans
Journal:  Arch Phys Med Rehabil       Date:  1993-11       Impact factor: 3.966

10.  Comparison of isokinetic measurements with test repetitions.

Authors:  R H Mawdsley; J J Knapik
Journal:  Phys Ther       Date:  1982-02
View more
  7 in total

1.  The assessment of neuromuscular fatigue during 120 min of simulated soccer exercise.

Authors:  Stuart Goodall; Kevin Thomas; Liam David Harper; Robert Hunter; Paul Parker; Emma Stevenson; Daniel West; Mark Russell; Glyn Howatson
Journal:  Eur J Appl Physiol       Date:  2017-02-28       Impact factor: 3.078

2.  FUNCTIONAL OUTCOMES AFTER DISTAL BICEPS BRACHII REPAIR: A CASE SERIES.

Authors:  Christine L Redmond; Tim Morris; Charissa Otto; Tanisha Zerella; John G Semmler; Taaibos Human; Joideep Phadnis; Gregory I Bain
Journal:  Int J Sports Phys Ther       Date:  2016-12

3.  Bone quality and bone mass as assessed by quantitative ultrasound and dual energy x ray absorptiometry in women with rheumatoid arthritis: relationship with quadriceps strength.

Authors:  O R Madsen; O H Sørensen; C Egsmose
Journal:  Ann Rheum Dis       Date:  2002-04       Impact factor: 19.103

Review 4.  Reliability of power in physical performance tests.

Authors:  W G Hopkins; E J Schabort; J A Hawley
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

5.  NemaFlex: a microfluidics-based technology for standardized measurement of muscular strength of C. elegans.

Authors:  Mizanur Rahman; Jennifer E Hewitt; Frank Van-Bussel; Hunter Edwards; Jerzy Blawzdziewicz; Nathaniel J Szewczyk; Monica Driscoll; Siva A Vanapalli
Journal:  Lab Chip       Date:  2018-07-24       Impact factor: 6.799

6.  Practice day may be unnecessary prior to testing knee extensor strength in young healthy adults.

Authors:  Jamie E Hibbert; Anthony S Kulas; Patrick M Rider; Zachary J Domire
Journal:  Int Biomech       Date:  2020-12

7.  Short-term isokinetic training versus isotonic training: effects on asymmetry in strength of thigh muscles.

Authors:  Dragana Golik-Peric; Miodrag Drapsin; Borislav Obradovic; Patrik Drid
Journal:  J Hum Kinet       Date:  2011-12-25       Impact factor: 2.193

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.