Literature DB >> 8239959

Reliability of isokinetic muscle strength testing in 45- to 78-year-old men and women.

W R Frontera1, V A Hughes, G E Dallal, W J Evans.   

Abstract

The test-retest reliability of isokinetic muscle strength testing was determined in 45- to 78-year-old men (N = 71; mean age = 60.2 years) and women (N = 107; mean age = 60.0 years). The dynamic muscle strength of the knee and elbow extensor (KE, EE) and flexor (KF, EF) muscle groups was measured at slow (60 degrees/sec) and fast (K = 240 degrees/sec; E = 180 degrees/sec) angular velocities using a Cybex II isokinetic dynamometer on two occasions seven to ten days apart. The mean peak torque in the second test was significantly higher (p < 0.001) in all muscle groups and both angular velocities tested in both sexes. The angle at which peak torque occurred did not change from the first to the second test except in the KF of females tested at 60 degrees/sec. Pearson's correlation coefficients (CCs; p < 0.01) in males ranged from .68 to .77 in the knee and from .71 to .84 in the elbow. In females, the CCs (p < 0.01) ranged from .58 to .74 in the knee and from .67 to .78 in the elbow. Thus in a large number of older men and women at least two tests may be necessary to determine isokinetic peak torque.

Entities:  

Mesh:

Year:  1993        PMID: 8239959

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  20 in total

1.  Factors related to postmenopausal muscle performance: a cross-sectional population-based study.

Authors:  Joonas Sirola; Toni Rikkonen; Heikki Kröger; Risto Honkanen; Marjo Tuppurainen; Olavi Airaksinen; Seppo Saarikoski
Journal:  Eur J Appl Physiol       Date:  2004-08-14       Impact factor: 3.078

2.  Responses of old men to repeated bouts of eccentric exercise of the elbow flexors in comparison with young men.

Authors:  A P Lavender; K Nosaka
Journal:  Eur J Appl Physiol       Date:  2006-06-10       Impact factor: 3.078

3.  Reliability of the one-repetition maximum test based on muscle group and gender.

Authors:  Dong-Il Seo; Eonho Kim; Christopher A Fahs; Lindy Rossow; Kaelin Young; Steven L Ferguson; Robert Thiebaud; Vanessa D Sherk; Jeremy P Loenneke; Daeyeol Kim; Man-Ki Lee; Kyung-Hoon Choi; Debra A Bemben; Michael G Bemben; Wi-Young So
Journal:  J Sports Sci Med       Date:  2012-06-01       Impact factor: 2.988

4.  Eccentric and concentric isokinetic knee flexion and extension: a reliability study using the Cybex 6000 dynamometer.

Authors:  R C Li; Y Wu; N Maffulli; K M Chan; J L Chan
Journal:  Br J Sports Med       Date:  1996-06       Impact factor: 13.800

5.  Exercise in patients receiving hematopoietic stem cell transplantation: lessons learned and results from a feasibility study.

Authors:  Eileen Danaher Hacker; Janet L Larson; David Peace
Journal:  Oncol Nurs Forum       Date:  2011-03       Impact factor: 2.172

6.  Torque, total work, power, torque acceleration energy and acceleration time assessed on a dynamometer: reliability of knee and elbow extensor and flexor strength measurements.

Authors:  O R Madsen
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

7.  Impairment and recovery of left motor function in patients with right hemiplegia.

Authors:  P Marque; A Felez; M Puel; J F Demonet; B Guiraud-Chaumeil; C F Roques; F Chollet
Journal:  J Neurol Neurosurg Psychiatry       Date:  1997-01       Impact factor: 10.154

8.  Reliability and Validity of EN-TreeM Dynamometer for Measurement of Shoulder Rotator Strength in Volleyball Players.

Authors:  Shahid Raza; Jamal Ali Moiz; Mohd Iqbal; Shalini Verma
Journal:  J Clin Diagn Res       Date:  2016-03-01

9.  Assessment of extensor and flexor strength in the individual gonarthrotic patient: interpretation of performance changes.

Authors:  O R Madsen; C Brot
Journal:  Clin Rheumatol       Date:  1996-03       Impact factor: 2.980

10.  Leg muscle strength is reduced in Parkinson's disease and relates to the ability to rise from a chair.

Authors:  Lisa M Inkster; Janice J Eng; Donna L MacIntyre; A Jon Stoessl
Journal:  Mov Disord       Date:  2003-02       Impact factor: 10.338

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.