Literature DB >> 889540

[Measurements of stability of operative osteosynthesis on the proximal femur (author's transl)].

H Schöttle, H D Sauer, K H Jungbluth.   

Abstract

Bending burdening of stable and unstable per- and subtrochanteral fractures after osteosynthesis with Y-nails (Küntscher), Ender-nails, 130 degrees and 95 degrees angled plates of the AO were tested in a comparative experimental study. The unstable fractures were also tested after treatment with osteosynthesis and additional application of bone cement in the artificial defect. The essential results were as follows: in the group of stable pertrochanteral fractures the Ender-nails bear in the mean 147 kp, the 130 degrees angle plate 200 kp. In the fracture-group with lacking medial support a highly burdening osteosynthesis could only be achieved by filling up the defects with bone cement. The 95 degrees-angled plate-osteosynthesis combined with bone cement bearing more than 300 kp was superior to the other procedures in the unstable per- and subtrochanteral fractures. In our investigation the stabilizing forces of muscles and fascia have not been taken into consideration.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 889540     DOI: 10.1007/bf00414828

Source DB:  PubMed          Journal:  Arch Orthop Unfallchir        ISSN: 0003-9330


  3 in total

1.  [Comparative strength analysis of selected osteosynthesis materials for pertrochanteric femoral fractures].

Authors:  E Teubner
Journal:  Chirurg       Date:  1975-12       Impact factor: 0.955

2.  [Load test on biomechanics and stability of combination-osteosyntheses in the femoral neck].

Authors:  G Ritter; A Grünert
Journal:  Langenbecks Arch Chir       Date:  1974

3.  [Behaviour of pertrochanteric fractures of the femur after condylar nailing under dynamical stress (author's transl)].

Authors:  H Martinek; B Wielke; E Egkher; P Fasol; R Passl; H Spängler
Journal:  Arch Orthop Unfallchir       Date:  1976-10-25
  3 in total
  4 in total

1.  [Dynamic force resistance of different osteosynthetic procedures in pertrochanteric femoral fractures (author's transl)].

Authors:  H D Sauer; H Schöttle; K H Jungbluth
Journal:  Arch Orthop Unfallchir       Date:  1977-09-29

2.  [Experimental studies of the loading capacity and deformation of pertrochanter osteotomies in extra and intramedullary osteosynthesis methods].

Authors:  W Friedl; T Mischkowsky; W Schult; W H Friedl
Journal:  Unfallchirurgie       Date:  1984-04

3.  [The connecting osteosynthesis and its problems in unstable pertrochanteric fractures of the femur (author's transl)].

Authors:  H U Langendorff; H D Sauer; H Schöttle
Journal:  Unfallchirurgie       Date:  1981

Review 4.  Union rates and functional outcome of double plating of the femur: systematic review of the literature.

Authors:  M F Lodde; M J Raschke; J Stolberg-Stolberg; J Everding; S Rosslenbroich; J C Katthagen
Journal:  Arch Orthop Trauma Surg       Date:  2021-01-23       Impact factor: 2.928

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.