Literature DB >> 1204400

[Comparative strength analysis of selected osteosynthesis materials for pertrochanteric femoral fractures].

E Teubner.   

Abstract

Four commercially available hip-fixation devices for stable fixation of pertrochanteric fractures were selected for a biomechanical evaluation, in order to determine, which construction would best support the load of weight-bearing in postoperative period. Intramedullar nailing by Lezius, Küntscher or Ender showed less bending moments than trifin nail-plates or extramedullar plate attachments with plate angles of 130 degrees or 95 degrees, so that bending tension of Lezius-nails were reduced compared to other implants in a proportion of 1.1,6:1,8:2,7. Whenever possible intramedullar nailing should be preferred. For extramedullar fixation of pathologic or unstable pertrochanteric fractures a double-T-plate was constructed, which shows a 3-fold load resistance of a Lezius-nail, 5-fold load-bearing of a 130 degree plate or a trifin nail combination and a 8-fold higher stress tolerance than a 95 degree-plate.

Entities:  

Mesh:

Year:  1975        PMID: 1204400

Source DB:  PubMed          Journal:  Chirurg        ISSN: 0009-4722            Impact factor:   0.955


  6 in total

1.  [Experimental studies on the stability of femoral head spongiosa in reference to a new type blade profile of a 130-degree angle plate].

Authors:  J Degreif; G Ritter; P Gèrard; K Wenda
Journal:  Unfallchirurgie       Date:  1990-10

2.  [Dynamic force resistance of different osteosynthetic procedures in pertrochanteric femoral fractures (author's transl)].

Authors:  H D Sauer; H Schöttle; K H Jungbluth
Journal:  Arch Orthop Unfallchir       Date:  1977-09-29

3.  [Measurements of stability of operative osteosynthesis on the proximal femur (author's transl)].

Authors:  H Schöttle; H D Sauer; K H Jungbluth
Journal:  Arch Orthop Unfallchir       Date:  1977-07-29

4.  [Experimental studies of the loading capacity and deformation of pertrochanter osteotomies in extra and intramedullary osteosynthesis methods].

Authors:  W Friedl; T Mischkowsky; W Schult; W H Friedl
Journal:  Unfallchirurgie       Date:  1984-04

5.  [Behaviour of pertrochanteric fractures of the femur after condylar nailing under dynamical stress (author's transl)].

Authors:  H Martinek; B Wielke; E Egkher; P Fasol; R Passl; H Spängler
Journal:  Arch Orthop Unfallchir       Date:  1976-10-25

6.  [Experimental studies of the load capacity of DHS osteosyntheses after various kinds of osteotomy in the area of the femoral trochanter].

Authors:  W Kaiser; V Gulielmos; G Fuhrmann; T Fritz; U Gross
Journal:  Langenbecks Arch Chir       Date:  1995
  6 in total