Literature DB >> 6730071

[Experimental studies of the loading capacity and deformation of pertrochanter osteotomies in extra and intramedullary osteosynthesis methods].

W Friedl, T Mischkowsky, W Schult, W H Friedl.   

Abstract

52 human femora were examined for stabilization behaviour of pertrochanteric osteotomies as well as the significance of the osteotomy angle by intramedullary osteosynthesis with Ender nailing and by extramedullary osteosynthesis using a 145 degrees angular plate. The maximum stress tolerance of both osteosynthesis procedures in femora with flat angle osteotomies is only marginally different, but the stress tolerance of Ender nailing is much less in the steep osteotomies. With steep osteotomy angle the plastic as well as the entire distorsion of the osteosynthesis increased considerably. The distorsion following Ender nailing compared to the 145 degrees angular plating is approximately the same. With increased osteoporosis a decrease of stability and an increase of distorsion is found. This correlation is even more pronounced by steep angular osteotomy. In some cases the exact opposite can be found, so that the maximum stress can not be concluded from the osteoporosis degree found on an x-ray.

Entities:  

Mesh:

Year:  1984        PMID: 6730071     DOI: 10.1007/BF02588379

Source DB:  PubMed          Journal:  Unfallchirurgie        ISSN: 0340-2649


  3 in total

1.  [Comparative strength analysis of selected osteosynthesis materials for pertrochanteric femoral fractures].

Authors:  E Teubner
Journal:  Chirurg       Date:  1975-12       Impact factor: 0.955

2.  [Measurements of stability of operative osteosynthesis on the proximal femur (author's transl)].

Authors:  H Schöttle; H D Sauer; K H Jungbluth
Journal:  Arch Orthop Unfallchir       Date:  1977-07-29

3.  Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis.

Authors:  M Singh; A R Nagrath; P S Maini
Journal:  J Bone Joint Surg Am       Date:  1970-04       Impact factor: 5.284

  3 in total
  3 in total

1.  [Experimental studies on the stability of femoral head spongiosa in reference to a new type blade profile of a 130-degree angle plate].

Authors:  J Degreif; G Ritter; P Gèrard; K Wenda
Journal:  Unfallchirurgie       Date:  1990-10

2.  [Manipulation of the step borer as cause of too shallow boring depth in the femoral neck with the gamma nail system].

Authors:  F Krug; D Baur; H Müller-Daniels; H-P Bruch
Journal:  Unfallchirurg       Date:  2003-10       Impact factor: 1.000

3.  [Ender nailing--an attempt at determining the position].

Authors:  K Benz; M Jasarevic; M Rüb
Journal:  Unfallchirurgie       Date:  1991-06
  3 in total