Literature DB >> 8892208

Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy.

R J Ordidge1, M Wylezinska, J W Hugg, E Butterworth, F Franconi.   

Abstract

Gradient localized spectroscopy techniques suffer from a well documented spatial localization error caused by the difference in chemical shifts between resonances. This results in the acquisition of spectra from partially overlapping spatial regions of the sample, with each resonance representing a different region. The image-selected in vivo spectroscopy technique uses hyperbolic secant inversion pulses, where the main limitation in reducing this error is in the RF power available for application of the selective RF pulse. This spatial localization error may be dramatically reduced by increasing, and temporally shaping, the gradient pulse during slice-selective spin inversion. The performance of these RF pulses have been experimentally verified.

Entities:  

Mesh:

Year:  1996        PMID: 8892208     DOI: 10.1002/mrm.1910360410

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  66 in total

1.  Magnetisation transfer effects of Q2TIPS pulses in ASL.

Authors:  Enrico De Vita; Matthias Günther; Xavier Golay; David L Thomas
Journal:  MAGMA       Date:  2011-12-28       Impact factor: 2.310

2.  Self-refocused adiabatic pulse for spin echo imaging at 7 T.

Authors:  Priti Balchandani; Mohammad Mehdi Khalighi; Gary Glover; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

3.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

4.  Optimization of background suppression for arterial spin labeling perfusion imaging.

Authors:  Nasim Maleki; Weiying Dai; David C Alsop
Journal:  MAGMA       Date:  2011-10-19       Impact factor: 2.310

5.  Limits of a localized magnetic resonance spectroscopy assay for ex vivo myocardial triacylglycerol.

Authors:  Robert D O'Connor; Robert J Gropler; Linda Peterson; Jean Schaffer; Joseph J H Ackerman
Journal:  J Pharm Biomed Anal       Date:  2007-09-01       Impact factor: 3.935

6.  Neurochemical abnormalities in patients with type 1 Gaucher disease on standard of care therapy.

Authors:  Reena V Kartha; James Joers; Marcia R Terluk; Abigail Travis; Kyle Rudser; Paul J Tuite; Neal J Weinreb; Jeanine R Jarnes; James C Cloyd; Gülin Öz
Journal:  J Inherit Metab Dis       Date:  2019-12-17       Impact factor: 4.982

7.  Distinct patterns of brain activity evoked by histamine-induced itch reveal an association with itch intensity and disease severity in atopic dermatitis.

Authors:  Y Ishiuji; R C Coghill; T S Patel; Y Oshiro; R A Kraft; G Yosipovitch
Journal:  Br J Dermatol       Date:  2009-05-15       Impact factor: 9.302

8.  Temporal course of perfusion in human masseter muscle during isometric contraction assessed by arterial spin labeling at 3T.

Authors:  Christina Schraml; Nina F Schwenzer; Petros Martirosian; Claus D Claussen; Fritz Schick
Journal:  MAGMA       Date:  2011-05-15       Impact factor: 2.310

9.  Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T.

Authors:  Marta Vidorreta; Evelyne Balteau; Ze Wang; Enrico De Vita; María A Pastor; David L Thomas; John A Detre; María A Fernández-Seara
Journal:  NMR Biomed       Date:  2014-09-26       Impact factor: 4.044

10.  Comparison of PASL, PCASL, and background-suppressed 3D PCASL in mild cognitive impairment.

Authors:  Sudipto Dolui; Marta Vidorreta; Ze Wang; Ilya M Nasrallah; Abass Alavi; David A Wolk; John A Detre
Journal:  Hum Brain Mapp       Date:  2017-07-24       Impact factor: 5.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.