Literature DB >> 8892145

Cancellous bone screw thread design and holding power.

S E Asnis1, J J Ernberg, M P Bostrom, T M Wright, R M Harrington, A Tencer, M Peterson.   

Abstract

This study was designed to isolate and evaluate the parameters of host density, outer diameter (OD), root diameter (RD), and pitch in cancellous bone screw design and their effect on holding power. Special emphasis was placed on screw pitch, which has been evaluated infrequently in the literature. Three groups of stainless steel V thread screws (group I, OD 4.5 mm, RD 3.0 mm; group II, OD 6.4 mm, RD 3.5 mm; group III, OD 6.4 mm, RD 4.2 mm) were machined with progressive increases in pitch from 12 to 32 threads per inch (TPI). Two densities of synthetic cancellous bone material (Pedilen, Ottobock, Minneapolis, MN, U.S.A.), 0.15 g/ml and 0.22 g/ml, were then prepared and molded into sheets 1.9 cm thick and the screw threads completely engaged. Push-out tests were performed using a servohydraulic testing machine (MTS, Minneapolis, MN, U.S.A.). Fifteen trials of each screw were tested in each material. The effect on holding power of the different parameters of the custom screws in order of importance was (a) host material density, (b) OD (c) pitch, and (d) RD. The groups with a 6.4-mm OD had a much greater holding power than did the group with a 4.5-mm OD (p < 0.001). A decrease in screw pitch (increased threads per inch) did itself have a significant improved effect on fixation for all groups in both pedilen densities (p < 0.001). In the two 6.4-mm screw groups studied, the difference in the two root diameters (4.2 mm vs. 3.5 mm) showed the smaller root diameter to give a greater holding power in the less dense 0.15 g/ml pedilen (p < 0.001). In the more dense 0.22 g/ml pedilen there was no difference (p = 0.26) between the root diameters. To optimize holding power, cancellous screws may be designed with a decreased pitch (increased TPI) over those commercially available today. Cannulated screws must have a larger cancellous thread root diameter to leave room for the central cannulation; this may decrease their holding power in less dense cancellous bone but not in denser bone.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8892145     DOI: 10.1097/00005131-199610000-00003

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  12 in total

1.  Mechanical behavior of screws in normal and osteoporotic bone.

Authors:  J Seebeck; J Goldhahn; M M Morlock; E Schneider
Journal:  Osteoporos Int       Date:  2004-10-27       Impact factor: 4.507

2.  Biomechanical testing of a novel osteosynthesis plate for the ulnar coronoid process.

Authors:  Johannes Kiene; Jorn Bogun; Nina Brockhaus; Klaus Waizner; Arndt-Peter Schulz; Robert Wendlandt
Journal:  Shoulder Elbow       Date:  2014-05-06

3.  New implant designs for fracture fixation in osteoporotic bone.

Authors:  J Goldhahn; J Seebeck; R Frei; B Frenz; I Antoniadis; E Schneider
Journal:  Osteoporos Int       Date:  2004-11-05       Impact factor: 4.507

4.  Assessment of the physical properties of laparoscopic myoma-fixation devices.

Authors:  H Tintara; P Aiyarak; W Mitarnun; A Geater
Journal:  Surg Endosc       Date:  2004-10-26       Impact factor: 4.584

5.  Comparison of Partially Threaded and Fully Threaded 4mm Cancellous Screws in Fixation of Medial Malleolar Fractures.

Authors:  Sayyed-Hadi Sayyed-Hosseinian; Farshid Bagheri; Mohammad-Hosien Ebrahimzadeh; Ali Moradi; Sogol Golshan
Journal:  Arch Bone Jt Surg       Date:  2020-11

6.  Staged Correction of Severe Thoracic Kyphosis in Patients with Multilevel Osteoporotic Vertebral Compression Fractures.

Authors:  Eyal Behrbalk; Ofir Uri; Yoram Folman; Marcus Rickert; Radek Kaiser; Bronek Maximilian Boszczyk
Journal:  Global Spine J       Date:  2015-12-02

7.  Assessment of the Breakaway Torque at the Posterior Pelvic Ring in Human Cadavers.

Authors:  Johannes Dominik Bastian; Mathias Bergmann; Ronald Schwyn; Marius Johann Baptist Keel; Lorin Michael Benneker
Journal:  J Invest Surg       Date:  2015-08-13       Impact factor: 2.533

8.  The effect of screw thread length on initial stability of Schatzker type 1 tibial plateau fracture fixation: a biomechanical study.

Authors:  Ahmet Salduz; Fevzi Birisik; Gokhan Polat; Bugra Bekler; Ergun Bozdag; Onder Kilicoglu
Journal:  J Orthop Surg Res       Date:  2016-11-22       Impact factor: 2.359

9.  Comparison and prediction of pullout strength of conical and cylindrical pedicle screws within synthetic bone.

Authors:  Wen-Chi Tsai; Po-Quang Chen; Tung-Wu Lu; Shing-Sheng Wu; Kao-Shang Shih; Shang-Chih Lin
Journal:  BMC Musculoskelet Disord       Date:  2009-04-30       Impact factor: 2.362

10.  Fracture fixation with two locking screws versus three non-locking screws: A biomechanical comparison in a normal and an osteoporotic bone model.

Authors:  B Grawe; T Le; S Williamson; A Archdeacon; L Zardiackas
Journal:  Bone Joint Res       Date:  2012-06-01       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.