Literature DB >> 8889877

Surgical management of infected permanent transvenous pacemaker systems: ten year experience.

P R Vogt1, K Sagdic, M Lachat, R Candinas, L K von Segesser, M I Turina.   

Abstract

BACKGROUND: Between January 1985 and June 1995, more than 1800 consecutive patients underwent implantation of a new permanent cardiac pacemaker at our institution. Thirty-six patients (0.02%) had 45 reinterventions for infected pacemaker systems.
METHODS: in group A, 24 of 27 patients received simultaneous implantation of a new pacemaker. One had reimplantation of the same pacemaker in the same pocket, and two did not require reimplantation. The leads were retained in 19 (70%) of the patients. In group B, nine patients underwent cardiopulmonary bypass or "pursestring" surgery for removal of an infected pacemaker; a new epicardial pacemaker system was simultaneously implanted in seven patients.
RESULTS: Identification of an infectious agent failed in 17 patients (47%), and Staphylococci were found in 15 patients (42%). The time from pacemaker implantation to onset of infection ranged from 1 month to 11 years (mean 31 months; median 19 months) and the time from onset of infection to surgical treatment from 1 month to 7 years (mean 7 months; median 2 months). The mean follow-up time is 74 months (range, 1 month to 10 years; median 5 years). There were 9 reoperations in 3 patients (16%) of group A for recurrent infection of their retained leads ultimately necessitating the use of open cardiac surgery. There was no early death; six patients died late due to unrelated causes.
CONCLUSIONS: Complete removal of all pacemaker leads is recommended; open heart surgery with the use of cardiopulmonary bypass is indicated in selected cases and is effective and safe.

Entities:  

Mesh:

Year:  1996        PMID: 8889877     DOI: 10.1111/j.1540-8191.1996.tb00036.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  13 in total

Review 1.  Pacemaker lead complications: when is extraction appropriate and what can we learn from published data?

Authors:  F A Bracke; A Meijer; L M van Gelder
Journal:  Heart       Date:  2001-03       Impact factor: 5.994

2.  Minimally invasive removal of infected pacemaker lead.

Authors:  N Hirata; S Ohtake; Y Sawa; A Amemiya; S Asada; H Matsuda
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2000-08

3.  Cardiac device-related endocarditis: Epidemiology, pathogenesis, diagnosis and treatment - a review.

Authors:  Shimon Edelstein; Malka Yahalom
Journal:  Int J Angiol       Date:  2009

4.  Emergent permanent pacemaker implantation in a premature 1,502 g neonate.

Authors:  Shin Takabayashi; Hisato Ito; Hideto Shimpo; Hirohumi Sawada; Yoshihide Mitani; Yoshihiro Komada
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-04

Review 5.  Endovascular extraction techniques for pacemaker and ICD lead extraction: Part 1.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-04       Impact factor: 2.380

Review 6.  Endovascular extraction techniques: Part 2: Complications and indications.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-05       Impact factor: 2.380

Review 7.  [Implant infections. What must an internist know?].

Authors:  W Zimmerli
Journal:  Internist (Berl)       Date:  2005-06       Impact factor: 0.743

8.  Sudden death under successful medical management of sick sinus syndrome after cardiac pacing discontinuation.

Authors:  Satoru Okumura; Masatoshi Kawata; Satoshi Niu; Koichi Ohga
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2002-10

Review 9.  Micafungin for Candida albicans pacemaker-associated endocarditis: a case report and review of the literature.

Authors:  Carlo Tascini; Maria Grazia Bongiorni; Enrico Tagliaferri; Antonello Di Paolo; Sarah Flammini; Ezio Soldati; Alessandro Leonildi; Andrea Di Cori; Francesco Menichetti
Journal:  Mycopathologia       Date:  2012-10-17       Impact factor: 2.574

10.  Long-term outcome of complete cardiovascular implantable electronic device removal with cardiopulmonary bypass.

Authors:  Masaho Okada; Yuji Narita; Yoshimori Araki; Hideki Oshima; Akihiko Usui; Yuichi Ueda
Journal:  J Artif Organs       Date:  2013-01-20       Impact factor: 1.731

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.