Literature DB >> 11002588

Minimally invasive removal of infected pacemaker lead.

N Hirata1, S Ohtake, Y Sawa, A Amemiya, S Asada, H Matsuda.   

Abstract

A 37-year-old woman with sick sinus syndrome suffered complications with recurring local infection at the generator pocket. Repeated debridement and antibiotic therapy was ineffective. Several attempts to remove leads via the implantation vein by direct traction were unsuccessful. We operated using cardiopulmonary bypass and applied a minimally invasive lower ministernotomy to obtain pleasing cosmetic results. After a right atriotomy, leads were removed. The minimally invasive approach gave satisfactory results, especially cosmetically.

Entities:  

Mesh:

Year:  2000        PMID: 11002588     DOI: 10.1007/BF03218194

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  6 in total

1.  Intravascular techniques for extraction of permanent pacemaker leads.

Authors:  C L Byrd; S J Schwartz; N Hedin
Journal:  J Thorac Cardiovasc Surg       Date:  1991-06       Impact factor: 5.209

Review 2.  Minimally invasive cardiac surgery: current status and perspective.

Authors:  H Matsuda; Y Sawa; T Takahashi; N Hirata; S Ohtake
Journal:  Artif Organs       Date:  1998-09       Impact factor: 3.094

3.  [Removal of the endocardial pacemaker leads--experience with 16 leads in 10 patients].

Authors:  S Hasegawa; T Morimoto; N Matsuyama; J Okamoto; Y Sawada; K Kondo; K Asada; S Sasaki
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-05

4.  Surgical management of infected permanent transvenous pacemaker systems: ten year experience.

Authors:  P R Vogt; K Sagdic; M Lachat; R Candinas; L K von Segesser; M I Turina
Journal:  J Card Surg       Date:  1996 May-Jun       Impact factor: 1.620

5.  Autopsy findings with permanent pervenous pacemakers.

Authors:  S J Robboy; J W Harthorne; R C Leinbach; C A Sanders; W G Austen
Journal:  Circulation       Date:  1969-04       Impact factor: 29.690

6.  Minimally invasive cardiac valve surgery improves patient satisfaction while reducing costs of cardiac valve replacement and repair.

Authors:  L H Cohn; D H Adams; G S Couper; D P Bichell; D M Rosborough; S P Sears; S F Aranki
Journal:  Ann Surg       Date:  1997-10       Impact factor: 12.969

  6 in total
  1 in total

1.  Entire removal of screw-in pacing leads 3 years after implantation.

Authors:  Yasuyuki Shimada
Journal:  J Rural Med       Date:  2011
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.